Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993830 DEA: 080H7914 EFIS: 0821000072
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-5.1/5.8
Work Description: RAMP METERING SYSTEM, HMA, RHMA, AND ROADWAY EXCAVATION.
Location Description: SAN BERNARDINO COUNTY IN RANCHO CUCAMONGA FROM FOOTHILL BOULEVARD UNDERCROSSING TO 0.4 MILE NORTH OF FOOTHILL BOULEVARD UNDERCROSSING
Contractor Name: Mike Muhsin
Contractor Address: 1852 La Palma Ace 377, Buena Park, CA 90620
Resident Engineer: Dominic Ehirim Structure Rep.: Unknown
DIME Sample ID: 2023-02-03-21
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 02/03/2023
Date that the sample was received by the laboratory/organization performing the testing: 02/07/2023
The quantity of what the sample constitutes: 2 BOXES
A brief description of the sample: 3/4" RHMA-G-SP R15 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0140G-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Corona
DIME Test ID: 2023-02-03-21-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 02/16/2023
Date Tested: 02/09/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2143.7 g
|
Corrected Asphalt Binder Content
|
7.4 %
|
Mass Loss
|
159.5 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
-0.06 %
|
Moisture Content
|
no data0 %
|
Temperature Compensation Factor
|
0.1 %
|
Test Temperature
|
538 F
|