Print Report | Back to Sample Detail

Sample Record for 2023-01-24-18

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215348 DEA: 060U4204 EFIS: 0616000004 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-99-R4.9/11.6
Work Description: CONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location Description: FRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Rd. Suite 200, Westlake Village CA 91361
Resident Engineer: Chris Wilfong Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-01-24-18
TL Number from the TL Form: 23-A-001
Sample Submitted By Organization: CT D06 - Fresno Field Laboratory
Sample Organization Contact: (559) 383-5498
Type of Sample: Quality Control
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/24/2023
Date that the sample was received by the laboratory/organization performing the testing: 01/30/2023
The quantity of what the sample constitutes: 293 tons
A brief description of the sample: 3/4" HMA-A, PG 70-10
From where was the sample collected: Job Site
Laboratory sample identification: 23-A-001
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan, Ashlan

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 12
Sublot number: 1
HMA Mix Number: 221534
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 2

DIME Test ID: 2023-01-24-18-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 02/03/2023
Date Tested: 02/01/2023
Submitted By Organization: CT D06 - Fresno Field Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: doug.lambert@dot.ca.gov
Organization Phone:
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent Air Voids 3.3 %
Percent Air Voids 2 3.7 %
Percent Air Voids 3 3.2 %
Average Percent Air Voids 3.4 %

Test 2 of 2

DIME Test ID: 2023-01-24-18-3
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 02/03/2023
Date Tested: 02/02/2023
Submitted By Organization: CT D06 - Fresno Field Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: doug.lambert@dot.ca.gov
Organization Phone:
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2074 g
Corrected Asphalt Binder Content 4.35 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data0 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 F