Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215348 DEA: 060U4204 EFIS: 0616000004
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-99-R4.9/11.6
Work Description: CONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location Description: FRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Rd. Suite 200, Westlake Village CA 91361
Resident Engineer: Chris Wilfong Structure Rep.: Unknown
DIME Sample ID: 2022-12-22-49
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/22/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/23/2022
The quantity of what the sample constitutes: 1000 CY
A brief description of the sample: CRCP
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Security Paving batch plant
The concrete mix design number: G3-22-PCC-291
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SKIPLOADER TO WHEELBARROW
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-12-22-49-1
Test Method: ASTM C78-18: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading)
Verified Date: 01/19/2023
Date Tested: 01/19/2023
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens
|
3
|
Unit system used?
|
US Units
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
Is a beam dimensional correction factor used?
|
No
|
Modulus of rupture
|
730 psi
|
Modulus of rupture 2
|
740 psi
|
Modulus of rupture 3
|
710 psi
|
Modulus of rupture average
|
725 psi
|