Sample Record for 2022-11-10-52
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214524 DEA: 07304504 EFIS: 0714000067
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-57-R0.0/R4.5
Work Description: CONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK.
Location Description: LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION
Contractor Name: Griffith Company
Contractor Address: 3050 E. Birch Street, Brea, CA 92821
Resident Engineer: Martin Sandoval Structure Rep.: Avtar Bains
Sample Information
DIME Sample ID: 2022-11-10-52
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 11/10/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/11/2022
The quantity of what the sample constitutes: 10 Cubic Yards
A brief description of the sample: CRCP Beams
From where was the sample collected: Job Site
Laboratory sample identification: 22-3024
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard Batch Plant
Material Information
The concrete mix design number: 57030SL
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 13430
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 3
DIME Test ID: 2022-11-10-52-1
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nhoffmann@altavistasolutions.com
Organization Phone: (510) 542-9827
This test has been superseded on 01/05/2023. The corrected test ID is: 2022-11-10-52-3
Reason: retested
Test 2 of 3
DIME Test ID: 2022-11-10-52-2
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 01/05/2023
Date Tested: 11/10/2022
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 3 of 3
DIME Test ID: 2022-11-10-52-3
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Verified Date: 01/05/2023
Date Tested: 12/08/2022
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
The test was superseded from test ID: 2022-11-10-52-1
Test Result Compliance:
Additional Comments When Verified:
|
Number of specimens
|
2
|
|
Unit system used?
|
US Units
|
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
|
Is a beam dimensional correction factor used?
|
Yes
|
|
Modulus of rupture average
|
690 psi
|
|
Modulus of rupture
|
710 psi
|
|
Modulus of rupture 2
|
670 psi
|
|
Age of specimen
|
28 days
|