Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042K8404 Cty SOL Rte 29 PM 0.0,0.8/1.6 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Noel Aquino |
Date Reported: |
01/18/2023 |
|
Address: |
TL Number: |
211042 |
||
City: |
||||
Project Name: HMA, STRUCTURAL CONCRETE, CIDH PILING AND REBAR. |
||||
Prime Contractor: OC Jones & Sons Inc |
||||
Sample Taken Date: |
12/21/2022 |
Mix Design: |
D10115EA |
|
Contractor: Unknown |
Location : SOLANO COUNTY IN VALLEJO AT ROUTE 80/29 SEPARATION AND ON ROUTE 80 FROM 0.2 MILE NORTH OF CARQUINEZ BRIDGE TOLL PLAZA TO 0.3 MILE SOUTH OF MAGAZINE STREET OVERCROSSING |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.01 | 12.63 | 77301 | 6121.0 | 4 |
2 | 4.00 | 12.57 | 86981 | 6922.0 | 4 |
3 | 4.00 | 12.57 | 86932 | 6918 | 4 |
DIME Test ID: 2022-12-21-34-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 6650
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing