Print Report | Back to Sample Detail

Sample Record for 2022-11-01-127

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-11-01-127
TL Number from the TL Form:
Sample Submitted By Organization: Sierra Pacific Materials
Sample Organization Contact: (805) 423-2327
Type of Sample: Quality Control
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/01/2022
The quantity of what the sample constitutes: JMF
A brief description of the sample: 1/2 HMA
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SPM Avenal

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2022-11-01-127-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/13/2022
Date Tested: 12/13/2022
Submitted By Organization: Sierra Pacific Materials
Organization Address: 45315 Lost Hills Road,
Organization City: Coalinga
Organization State: CA
Organization Zipcode: 93210
Organization Email: mdavis@papichconstruction.com
Organization Phone: (805) 423-2327
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.3 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test

DIME Test ID: 2022-11-01-127-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 12/13/2022
Date Tested: 12/13/2022
Submitted By Organization: Sierra Pacific Materials
Organization Address: 45315 Lost Hills Road,
Organization City: Coalinga
Organization State: CA
Organization Zipcode: 93210
Organization Email: mdavis@papichconstruction.com
Organization Phone: (805) 423-2327
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2.337
Bulk Specific Gravity 2 2.335
Bulk Specific Gravity 3 2.338
Average Bulk Specific Gravity 2.337

Test

DIME Test ID: 2022-11-01-127-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/15/2022
Date Tested: 12/15/2022
Submitted By Organization: Sierra Pacific Materials
Organization Address: 45315 Lost Hills Road,
Organization City: Coalinga
Organization State: CA
Organization Zipcode: 93210
Organization Email: mdavis@papichconstruction.com
Organization Phone: (805) 423-2327
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
Number of tests 3
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Specific Gravity for Sample 1 no data
Specific Gravity for Sample 2 no data
Specific Gravity for Sample 3 no data
Average Specific Gravity 2.435
Theoretical maximum density at 25°C (77°F) no data

Test

DIME Test ID: 2022-11-01-127-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 12/15/2022
Date Tested: 12/15/2022
Submitted By Organization: Sierra Pacific Materials
Organization Address: 45315 Lost Hills Road,
Organization City: Coalinga
Organization State: CA
Organization Zipcode: 93210
Organization Email: mdavis@papichconstruction.com
Organization Phone: (805) 423-2327
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
Percent Air Voids 4 %
Percent Air Voids 2 4.1 %
Percent Air Voids 3 4 %
Average Percent Air Voids 4 %