Print Report | Back to Sample Detail

Sample Record for 2022-09-11-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993545 DEA: 07328504 EFIS: 0716000178 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R44.7/R52.1
Work Description: INSTALL DPP INFILTRATION AREA & CONSTRUCT MAINTENANCE VEHICLE PULLOUT
Location Description: LOS ANGELES COUNTY FROM 0.4 MILE EAST OF SOUTH LONE HILL AVENUE UNDERCROSSING TO COUNTY LINE
Contractor Name: Chumo Construction
Contractor Address: 14425 Joanbridge St, Baldwin Park, CA 91706
Resident Engineer: Sushilkumar Chaudhari Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-09-11-9
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/11/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/05/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0764-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan-Irwindale

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2022-09-11-9-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 12/15/2022
Date Tested: 12/08/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 59 C
Softening Point Sample 2 59 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2022-09-11-9-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 12/15/2022
Date Tested: 12/09/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 37 0.1 mm

Test 3 of 3

DIME Test ID: 2022-09-11-9-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 12/15/2022
Date Tested: 12/09/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 4 mm
Final Dial reading (F1) 78 mm
Ball Penetration (P2) 5 mm
Final Dial reading (F2) 80 mm
Ball Penetration (P3) 4 mm
Final Dial reading (F3) 77 mm
Resilience 1 26 %
Resilience 2 25 %
Resilience 3 27 %
Average Resilience 26 %
Minutes Reaction no data