Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214438 DEA: 080G6914 EFIS: 0815000184
QA Service Level: 1
DIST-CO-RTE-PM: 08---
Work Description: RELINE OR REPLACE CULVERTS
Location Description: SAN BERNARDINO COUNTY IN AND NEAR SAN BERNARDINO FROM 48TH STREET TO ROUTE 18/138 SEPARATION
Contractor Name: SUKUT CONSTRUCTION, LLC.
Contractor Address: Unknown
Resident Engineer: NHAN NGUYEN Structure Rep.: Unknown
DIME Sample ID: 2022-11-21-32
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Per Request
Type of Material: Asphalt Binder
Sample Taken Date: 11/21/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/01/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: PG Asphalt Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0762-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Matich Lytle Creek
Performance Grade: PG 64-28
Modified: Yes
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Marathon Petroleum Co. LP - Tuscon AZ
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2022-11-21-32-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: -0.104 + 0.006 = 0.098
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Any material loss from containers during heating process/testing?
|
No
|
Mass of empty container #1
|
167.289 grams
|
Mass of empty container #2
|
169.569 grams
|
Mass of container #1 before test (m1i)
|
202.352 grams
|
Mass of container #2 before test (m2i)
|
204.703 grams
|
Mass of container #1 after test (m1f)
|
202.315 grams
|
Mass of container #2 after test (m2f)
|
204.667 grams
|
Average mass change
|
-0.104 percent
|
DIME Test ID: 2022-11-21-32-2
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: ORIGINAL
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
Original binder
|
Phase Angle (δ) (for the 10 cycles)
|
55.7 degree
|
Dynamic Shear, G*/sin(δ)
|
1.93 kPa
|
(G*) x sin(δ)=
|
no data
|
DIME Test ID: 2022-11-21-32-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
63.3 degree
|
Dynamic Shear, G*/sin(δ)
|
2.58 kPa
|
DIME Test ID: 2022-11-21-32-4
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
Time of test
|
8:45 HH:MM
|
Test Temperature
|
135.0 C
|
Speed
|
20 rpm
|
Spindle size
|
21 in
|
Torque
|
79.0 %
|
Viscosity reading #1 (A)
|
1.978 Pa-s
|
Viscosity reading #2 (B)
|
2.004 Pa-s
|
Viscosity reading #3 (C)
|
1.981 Pa-s
|
Average viscosity
|
1.988 Pa-s
|
DIME Test ID: 2022-11-21-32-5
Test Method: AASHTO T228-09r13: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
DIME Test ID: 2022-11-21-32-6
Test Method: AASHTO T44-18: Standard Method of Test for Solubility of Bituminous Materials
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Was test performed on residue from distillation or evaporation?
|
NA
|
Soluble, percent
|
99.3 %
|
Insoluble, percent
|
0.7 %
|
DIME Test ID: 2022-11-21-32-7
Test Method: AASHTO T301-22: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
Data has not been verified.