Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214697 DEA: 07307104 EFIS: 0714000213
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-101-32.8
Work Description: CONSTRUCT BRIDGE.
Location Description: LOS ANGELES COUNTY IN AND NEAR AGOURA HILLS FROM 0.1 MILE WEST OF LIBERTY CANYON ROAD UNDERCROSSING TO 0.6 MILE EAST OF PALO COMADO OVERCROSSING
Contractor Name: CA Rasmussen
Contractor Address: 28548 LIVINGSTON AVENUE, VALENICA CA 91355
Resident Engineer: Sam Toutounchian Structure Rep.: Darwin Vargas
DIME Sample ID: 2022-11-22-3
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Soil
Sample Taken Date: 11/22/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/22/2022
The quantity of what the sample constitutes: 3150 sqft
A brief description of the sample: Aggregate Base
From where was the sample collected: Job Site
Laboratory sample identification: 22-3096
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Ramco
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: CTM 231 Test Holes
Where the material sample would have been placed if not sampled:
DIME Test ID: 2022-11-22-3-1
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 11/22/2022
Date Tested: 11/22/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Is oversize material
|
No
|
In-place wet density
|
2.07
|
Highest adjust wet density
|
2.21
|
Relative compaction
|
94
|
% Moisture
|
9.3 %
|
Optimum Moisture
|
9.3 %
|
DIME Test ID: 2022-11-22-3-2
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 11/22/2022
Date Tested: 11/22/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Standard Count Density
|
2315 g/cc
|
Count or Density 1
|
2.18 g/cc
|
Count or Density 2
|
1.96 g/cc
|
Count or Density 3
|
2.07 g/cc
|
Standard Count Moisture
|
668 g/cc
|
Moisture Count 1
|
0.19 g/cc
|
Moisture Count 2
|
0.16 g/cc
|
Moisture Count 3
|
0.18 g/cc
|
Sum of Count or Density
|
6.21 g/cc
|
Average of Count or Density
|
2.07 g/cc
|
Sum of Moisture Count
|
0.53 g/cc
|
Average of Moisture Count
|
0.18 g/cc
|
Calculated Percent Relative Compaction
|
93.7 %
|
Reported Percent Relative Compaction
|