Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214524 DEA: 07304504 EFIS: 0714000067
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-57-R0.0/R4.5
Work Description: CONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK.
Location Description: LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION
Contractor Name: Griffith Company
Contractor Address: 3050 E. Birch Street, Brea, CA 92821
Resident Engineer: Martin Sandoval Structure Rep.: Avtar Bains
DIME Sample ID: 2022-10-31-51
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Per Request
Type of Material: Asphalt Binder
Sample Taken Date: 10/31/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/16/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: PG Asphalt Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0741-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan-Irwindale
Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Lunday Thagard Company-World Oil - South Gate CA
Multigrade: Yes
Multigrade Type: PG 64-16 / PG 64-10
Asphalt Binder Mix Number:
DIME Test ID: 2022-10-31-51-1
Test Method: AASHTO T228-09r13: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Verified Date: 11/23/2022
Date Tested: 11/18/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
DIME Test ID: 2022-10-31-51-2
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 11/23/2022
Date Tested: 11/18/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: -0.050 + 0.006 =-0.044
Test Result Compliance: complies
Additional Comments When Verified:
|
Is mass change based on one or two containers?
|
Two
|
|
Any material loss from containers during heating process/testing?
|
No
|
|
Mass of empty container #1
|
167.3 grams
|
|
Mass of empty container #2
|
169.575 grams
|
|
Mass of container #1 before test (m1i)
|
202.337 grams
|
|
Mass of container #2 before test (m2i)
|
204.723 grams
|
|
Mass of container #1 after test (m1f)
|
202.32 grams
|
|
Mass of container #2 after test (m2f)
|
204.705 grams
|
|
Average mass change
|
-0.05 percent
|
DIME Test ID: 2022-10-31-51-3
Test Method: AASHTO T44-18: Standard Method of Test for Solubility of Bituminous Materials
Verified Date: 11/23/2022
Date Tested: 11/18/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Was test performed on residue from distillation or evaporation?
|
NA
|
|
Soluble, percent
|
99.5 %
|
|
Insoluble, percent
|
0.5 %
|
DIME Test ID: 2022-10-31-51-4
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 11/23/2022
Date Tested: 11/18/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: Original
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
Original binder
|
|
Phase Angle (δ) (for the 10 cycles)
|
87.2 degree
|
|
Dynamic Shear, G*/sin(δ)
|
1.42 kPa
|
|
(G*) x sin(δ)=
|
no data
|
DIME Test ID: 2022-10-31-51-5
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 11/23/2022
Date Tested: 11/18/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is viscosity reading in cP/Pa-s?
|
cP
|
|
Time of test
|
06:25 HH:MM
|
|
Test Temperature
|
135 C
|
|
Speed
|
100 rpm
|
|
Spindle size
|
21 in
|
|
Torque
|
79 %
|
|
Viscosity reading #1 (A)
|
0.391 cP
|
|
Viscosity reading #2 (B)
|
0.399 cP
|
|
Viscosity reading #3 (C)
|
0.395 cP
|
|
Average viscosity
|
0.395 Pa-s
|
DIME Test ID: 2022-10-31-51-6
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 11/23/2022
Date Tested: 11/18/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
RTFO residue
|
|
Test Plate Diameter
|
25 mm
|
|
Phase Angle (δ) (for the 10 cycles)
|
84.4 degree
|
|
Dynamic Shear, G*/sin(δ)
|
3.72 kPa
|
DIME Test ID: 2022-10-31-51-7
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
Data has not been verified.