Sample Record for 2022-11-04-41

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993195 DEA: 07332504 EFIS: 0716000270 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-2-26.4/79.8
Work Description: INSTALL METAL BEAM GUARDRAILS.
Location Description: LOS ANGELES COUNTY NEAR LA CANADA FLINTRIDGE FROM BAY TREE ROAD TO BIG PINES HIGHWAY
Contractor Name: DREAMBUILDER CONSTRUCTION CORP DBA DREAMBUILDER
Contractor Address: Unknown
Resident Engineer: Bill Tran Danglong Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-11-04-41
TL Number from the TL Form: 019213
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/04/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/15/2022
The quantity of what the sample constitutes: 42 tons out
A brief description of the sample: 3/8" HMA DIKE
From where was the sample collected: Manufacturer
Laboratory sample identification: 22-0355
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Sun Valley

Material Information

HMA Type: Type A HMA
HMA Grading: 3/8 inch
Lot number:
Sublot number:
HMA Mix Number: 421500
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2022-11-04-41-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/17/2022
Date Tested: 11/17/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of the specimen basket assembly no data
Mass of the specimen and specimen basket assembly prior to ignition no data
Mass of HMA Sample prior to ignition 1552.9 g
Corrected Asphalt Binder Content 6.79 %
Mass Loss no data
Mass of aggregate remaining after ignition 1447.5 g
Correction Factor (Percent by mass of HMA Specimen) no data0 %
Moisture Content no data0 %
Temperature Compensation Factor no data
Test Temperature 1000.4 F