Print Report | Back to Sample Detail

Sample Record for 2022-11-03-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-11-03-15
TL Number from the TL Form:
Sample Submitted By Organization: Granite Construction Company - Tracy
Sample Organization Contact: (209) 234-3571
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 11/03/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/03/2022
The quantity of what the sample constitutes: 1
A brief description of the sample: 1/4" Chips
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vernalis Aggregate Source

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-39-0002
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Tunnel Pile
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2022-11-03-15-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 11/03/2022
Date Tested: 11/03/2022
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test: Submitted from JMF - Chris Escobar
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 60 %
Cumulative percent passing the #8 sieve 6 %
Cumulative percent passing the #16 sieve 2 %
Cumulative percent passing the #30 sieve 1 %
Cumulative percent passing the #50 sieve 1 %
Cumulative percent passing the #100 sieve 1 %
Cumulative percent passing the #200 sieve 0.8 %