Project Information

Project ID: 214993 DEA: 051F5004 EFIS: 0514000003 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101,135-70.6/71.2;0.1
Work Description: CONSTRUCT CONCRETE BRIDGE, BRIDGE REMOVAL, COLD PLANE, PLACE HMA.
Location Description: SANTA BARBARA COUNTY AT LOS ALAMOS ON ROUTE 101 FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ROUTE 101/135 SEPARATION AND ON ROUTE 135 AT ROUTE 101/135 SEPARATION
Contractor Name: CAL PORTLAND CONSTRUCTION
Contractor Address: 1625 E Donovan Road, Santa Maria, CA 93454
Resident Engineer: Jason Torres Structure Rep.: Alex Martinez

Sample Information

DIME Sample ID: 2022-10-24-27
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Sample Organization Contact:
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 10/24/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/24/2022
The quantity of what the sample constitutes: 66 CY
A brief description of the sample: 1 x 4 PCC Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Calportland Donovan

Material Information

The concrete mix design number: 590GM1060
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 5

DIME Test ID: 2022-10-24-27-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/01/2022
Date Tested: 10/31/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test: abutment #2 7 day
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Apparent mass of submerged cylinder 1 0 lb
Average diameter of cylinder 1 3.97 in
Average diameter of cylinder 2 3.98 in
Average diameter of cylinder 3 3.97 in
Cross sectional area of cylinder 1 12.39 in^2
Cross sectional area of cylinder 2 12.42 in^2
Cross sectional area of cylinder 3 12.37 in^2
Compressive strength (to nearest 10 psi) 3020 psi
Maximum load on cylinder 1 37041 lb
Maximum load on cylinder 2 37901 lb
Maximum load on cylinder 3 37526 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Correction factor for cylinder 3 1.00
Age of specimen 7 days
Age of specimen in hours 168 hours
Serial number of delivery ticket, if available no data

Test 2 of 5

DIME Test ID: 2022-10-24-27-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/21/2022
Date Tested: 11/21/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test: abutment #2 28 day
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Apparent mass of submerged cylinder 1 0 lb
Average diameter of cylinder 1 3.98 in
Average diameter of cylinder 2 3.98 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.44 in^2
Cross sectional area of cylinder 2 12.45 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4140 psi
Maximum load on cylinder 1 50112 lb
Maximum load on cylinder 2 52192 lb
Maximum load on cylinder 3 52653 lb
Type of fracture pattern of cylinder 1 4
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 0.00
Correction factor for cylinder 2 0.00
Correction factor for cylinder 3 0.00
Age of specimen 28 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available NA

Test 3 of 5

DIME Test ID: 2022-10-24-27-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 12/08/2022
Date Tested: 12/05/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test: abutment #2 42 day
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Apparent mass of submerged cylinder 1 0 lb
Average diameter of cylinder 1 3.97 in
Average diameter of cylinder 2 3.99 in
Average diameter of cylinder 3 3.97 in
Cross sectional area of cylinder 1 12.38 in^2
Cross sectional area of cylinder 2 12.51 in^2
Cross sectional area of cylinder 3 12.39 in^2
Compressive strength (to nearest 10 psi) 4340 psi
Maximum load on cylinder 1 54218 lb
Maximum load on cylinder 2 55703 lb
Maximum load on cylinder 3 51837 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Correction factor for cylinder 3 1.00
Age of specimen 42 days
Age of specimen in hours 1008 hours
Serial number of delivery ticket, if available 1809834

Test 4 of 5

DIME Test ID: 2022-10-24-27-4
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 11/01/2022
Date Tested: 10/24/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 83 F

Test 5 of 5

DIME Test ID: 2022-10-24-27-5
Test Method: CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete
Verified Date: 11/01/2022
Date Tested: 10/24/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Slump 5.25 inch