Print Report | Back to Sample Detail

Sample Record for 2022-10-20-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88887 DEA: PC-Barrier-STOCK EFIS: PC-Barrier-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for precast barrier rail stock material.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-10-20-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Stock
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/20/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/20/2022
The quantity of what the sample constitutes: 53
A brief description of the sample: 3/8" F436/A153/F2329 Flat Washer
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS Lindon UT

Material Information

Rocap Number(s):
Heat Number(s): 12127770
Nut Mfg. Lot Number(s): n/a
Washer Mfg. Lot Number(s): E2008
Bolt Specification: n/a
Bolt Length(s):
Nut Specification: n/a
Washer Specification: F436/A153/F2329
Finish: HDG
Diameter/Size: 3/8
Bolt Mfg. Lot Number: n/a
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):

Test Results

Test 1 of 6

DIME Test ID: 2022-10-20-2-1
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/28/2022
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E2008
Finish Coating ASTM F2329 - Hot Dip
Product Markings F436P
Size .375 in
Bolt Length no data in
Measurement Average 3.63 mils

Test 2 of 6

DIME Test ID: 2022-10-20-2-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/28/2022
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E2008
Finish Coating ASTM F2329 - Hot Dip
Product Markings F436P
Size .375 in
Bolt Length no data in
Measurement Average 3.18 mils

Test 3 of 6

DIME Test ID: 2022-10-20-2-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/28/2022
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E2008
Finish Coating ASTM F2329 - Hot Dip
Product Markings F436P
Size .375 in
Bolt Length no data in
Measurement Average 4.35 mils

Test 4 of 6

DIME Test ID: 2022-10-20-2-4
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/28/2022
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E2008
Finish Coating ASTM F2329 - Hot Dip
Product Markings F436P
Size .375 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 36.27
Spacing Ok

Test 5 of 6

DIME Test ID: 2022-10-20-2-5
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/28/2022
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E2008
Finish Coating ASTM F2329 - Hot Dip
Product Markings F436P
Size .375 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 34.1
Spacing Ok

Test 6 of 6

DIME Test ID: 2022-10-20-2-6
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/28/2022
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E2008
Finish Coating ASTM F2329 - Hot Dip
Product Markings F436P
Size .375 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 35.67
Spacing Ok