Print Report | Back to Sample Detail

Sample Record for 2022-09-07-94

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993802 DEA: 041W8804 EFIS: 0421000104 QA Service Level: 1
DIST-CO-RTE-PM: 04-SON-101-R54.2/R56.2
Work Description: COLD PLANE AC PAVEMENT AND PLACE RHMA (TYPE G).
Location Description: SONOMA COUNTY NEAR CLOVERDALE FROM ROUTE 101/128 SEPARATION TO MENDOCINO COUNTY LINE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: LEONARD BRAJNIKOFF Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-09-07-94
TL Number from the TL Form: 670375
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/07/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/18/2022
The quantity of what the sample constitutes: 1 Can
A brief description of the sample: rubber
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number: 1
Sublot number: 1
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 4

DIME Test ID: 2022-09-07-94-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 10/27/2022
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 26 0.1 mm

Test 2 of 4

DIME Test ID: 2022-09-07-94-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
This test has been superseded on 11/07/2022. The corrected test ID is: 2022-09-07-94-4
Reason: retested

Test 3 of 4

DIME Test ID: 2022-09-07-94-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 10/27/2022
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) no data0 mm
Final Dial reading (F1) 56 mm
Ball Penetration (P2) no data0 mm
Final Dial reading (F2) 60 mm
Ball Penetration (P3) no data0 mm
Final Dial reading (F3) 58 mm
Resilience 1 44 %
Resilience 2 40 %
Resilience 3 42 %
Average Resilience 42 %
Minutes Reaction no data

Test 4 of 4

DIME Test ID: 2022-09-07-94-4
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 11/07/2022
Date Tested: 11/03/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
The test was superseded from test ID: 2022-09-07-94-2
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 74 C
Softening Point Sample 2 74 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data