Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212737 DEA: 060S8304 EFIS: 0615000046
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-5-44.4-45.4
Work Description: TUMEY GULCH ABUTMENT REHAB BR# 42-0246L/R.
Location Description: IN FRESNO COUNTY AT TUMEY GULCH.
Contractor Name: Bruce Shumacher
Contractor Address: 2716 S Granite Ct, Fresno, CA 93706
Resident Engineer: Cary Cruz Structure Rep.: Ben Holton
DIME Sample ID: 2022-10-04-47
TL Number from the TL Form: C039987
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Quality Control
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/04/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/04/2022
The quantity of what the sample constitutes: 3 Boxes
A brief description of the sample: 3/4" HMA-A with 25% RAP
From where was the sample collected: Source
Laboratory sample identification: 022-082
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Coalinga
DIME Test ID: 2022-10-04-47-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/14/2022
Date Tested: 10/13/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Water
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of oven-dry sample in air for Sample 1
|
2570.6 grams
|
Mass of sample in water for Sample 1
|
1523.5 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.455
|
Theoretical maximum density at 25°C (77°F)
|
152.8 lb/ft^3
|
DIME Test ID: 2022-10-04-47-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 10/14/2022
Date Tested: 10/13/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids
|
3.8 %
|
Percent Air Voids 2
|
3.9 %
|
Percent Air Voids 3
|
4.0 %
|
Average Percent Air Voids
|
3.9 %
|
DIME Test ID: 2022-10-04-47-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 10/14/2022
Date Tested: 10/13/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity
|
2.361
|
Bulk Specific Gravity 2
|
2.360
|
Bulk Specific Gravity 3
|
2.358
|
Average Bulk Specific Gravity
|
2.360
|