Print Report | Back to Sample Detail

Sample Record for 2022-08-01-78

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215803 DEA: 081J0204 EFIS: 0817000182 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-R48.8/49.2
Work Description: CONSTRUCT DRAINAGE SYSTEM WITH STRUCTURAL CONCRETE HEADWALL AND CSP.
Location Description: RIVERSIDE COUNTY NEAR HEMET FROM 0.7 MILE TO 1.1 MILES EAST OF BLACKBURN ROAD
Contractor Name: Dreambuilder Construction Corporation
Contractor Address: 1324 E. Lawson Lane, Placentia, CA 92870
Resident Engineer: Nick Truong Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-08-01-78
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Department Acceptance
Type of Material: Aggregate
Sample Taken Date: 08/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/01/2022
The quantity of what the sample constitutes: 1 Bag of Combined Aggregate
A brief description of the sample: 3/4" HMA-SP
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA Corona

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-33-0005
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number: 105793
A detailed description of where the material sample was collected: Belt Cut at All American Corona Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2022-08-01-78-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 09/26/2022
Date Tested: 08/02/2022
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 96 %
Cumulative percent passing the 1/2 in. sieve 83 %
Cumulative percent passing the 3/8 in. sieve 74 %
Cumulative percent passing the #4 sieve 52 %
Cumulative percent passing the #8 sieve 35 %
Cumulative percent passing the #16 sieve 23 %
Cumulative percent passing the #30 sieve 15 %
Cumulative percent passing the #50 sieve 9 %
Cumulative percent passing the #100 sieve 6 %
Cumulative percent passing the #200 sieve 4.1 %

Test 2 of 2

DIME Test ID: 2022-08-01-78-2
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 09/26/2022
Date Tested: 08/02/2022
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 75