Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993771 DEA: 07325204 EFIS: 0716000082
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R36.7/R37.1
Work Description: San Gabriel River Bridge - CM/GC Project - Hinge And Diaphragm Repairs
Location Description: Los Angeles County - LOS ANGELES COUNTY IN IRWINDALE FROM 0.2 MILE EAST OF 0.7 MILE WEST OF IRWINDALE AVENUE OVECROSSING
Contractor Name: FLATIRON WEST INC
Contractor Address: 14726 Ramona Avenue, Suite 300, Chino, CA 91710
Resident Engineer: Moe Izadpanah Structure Rep.: Quynh Nguyen
DIME Sample ID: 2022-09-21-37
TL Number from the TL Form: 1044-04
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 09/21/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/23/2022
The quantity of what the sample constitutes: 10
A brief description of the sample: Concrete Cylinders 4x8
From where was the sample collected: Job Site
Laboratory sample identification: 1044-04
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: National
The concrete mix design number: S72073
The truck number from where the sample was collected: Not Provided
The batch plant ticket number from where the sample was collected: Not Provided
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: EB 210 STA 3510
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-09-21-37-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap Cured in accordance with ASTM C511
Verified Date: 10/04/2022
Date Tested: 09/28/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.63 in^2
|
|
Cross sectional area of cylinder 3
|
12.69 in^2
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Compressive strength (to nearest 10 psi)
|
3260 psi
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.01 in
|
|
Compressive strength of cylinder 1
|
3338.9 psi
|
|
Compressive strength of cylinder 2
|
3191.6 psi
|
|
Average diameter of cylinder 3
|
4.02 in
|
|
Compressive strength of cylinder 3
|
3248.2 psi
|
|
Maximum load on cylinder 1
|
42170 lb
|
|
Maximum load on cylinder 2
|
40310 lb
|
|
Maximum load on cylinder 3
|
41220 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
DIME Test ID: 2022-09-21-37-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap Cured in accordance with ASTM C511
Verified Date: 10/05/2022
Date Tested: 10/05/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.63 in^2
|
|
Cross sectional area of cylinder 3
|
12.63 in^2
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Compressive strength (to nearest 10 psi)
|
3880 psi
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.01 in
|
|
Compressive strength of cylinder 1
|
3938.2 psi
|
|
Compressive strength of cylinder 2
|
3779.1 psi
|
|
Average diameter of cylinder 3
|
4.01 in
|
|
Compressive strength of cylinder 3
|
3935.1 psi
|
|
Maximum load on cylinder 1
|
49740 lb
|
|
Maximum load on cylinder 2
|
47730 lb
|
|
Maximum load on cylinder 3
|
49700 lb
|
|
Type of fracture pattern of cylinder 1
|
1
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
1
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
14 days
|
DIME Test ID: 2022-09-21-37-3
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap Cured in accordance with ASTM C511
Verified Date: 10/12/2022
Date Tested: 10/12/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.63 in^2
|
|
Cross sectional area of cylinder 3
|
12.69 in^2
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Compressive strength (to nearest 10 psi)
|
4530 psi
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.01 in
|
|
Compressive strength of cylinder 1
|
4501.2 psi
|
|
Compressive strength of cylinder 2
|
4540.0 psi
|
|
Average diameter of cylinder 3
|
4.02 in
|
|
Compressive strength of cylinder 3
|
4553.2 psi
|
|
Maximum load on cylinder 1
|
56850 lb
|
|
Maximum load on cylinder 2
|
57340 lb
|
|
Maximum load on cylinder 3
|
57780 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
21 days
|
DIME Test ID: 2022-09-21-37-4
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap Cured in accordance with ASTM C511
Verified Date: 12/13/2022
Date Tested: 10/19/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.69 in^2
|
|
Cross sectional area of cylinder 2
|
12.69 in^2
|
|
Cross sectional area of cylinder 3
|
12.69 in^2
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Compressive strength (to nearest 10 psi)
|
4670 psi
|
|
Average diameter of cylinder 1
|
4.02 in
|
|
Average diameter of cylinder 2
|
4.02 in
|
|
Compressive strength of cylinder 1
|
4728.1 psi
|
|
Compressive strength of cylinder 2
|
4642.2 psi
|
|
Average diameter of cylinder 3
|
4.02 in
|
|
Compressive strength of cylinder 3
|
4647.8 psi
|
|
Maximum load on cylinder 1
|
60000 lb
|
|
Maximum load on cylinder 2
|
58910 lb
|
|
Maximum load on cylinder 3
|
58980 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|