|
Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044G0804 Cty SOL Rte 80 PM R10.4/30.2 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Justen Tatum |
Date Reported: |
07/23/2024 |
|
|
Address: |
TL Number: |
001 |
||
|
City: |
||||
|
Project Name: Highway widening, overhead signs, and electronic toll system. |
||||
|
Prime Contractor: O.C. JONES & SONS, INC. |
||||
|
Sample Taken Date: |
09/22/2022 |
Mix Design: |
1615759 |
|
|
Contractor: Unknown |
Location : In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
|||
|
Structure unique identifier: |
||||
|
Structure name: RW 4 |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.03 | 12.76 | 64948 | 5092.0 | 4 |
| 2 | 4.01 | 12.63 | 61907 | 4902.0 | 4 |
| 3 | 4.01 | 12.63 | 59271 | 4693 | 4 |
DIME Test ID: 2022-09-22-16-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4900
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
| Slump |
|---|
| 6 |
DIME Test ID: 2022-09-22-16-3
Certified By: Rose Saephan
ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
| Temperature |
|---|
| 69 |
DIME Test ID: 2022-09-22-16-4
Certified By: Rose Saephan
Test ID: 2022-09-22-16-3: Performed by RMA
Test ID: 2022-09-22-16-4: Performed by RMA
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing