Print Report | Back to Sample Detail

Sample Record for 2022-09-14-52

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212775 DEA: 024F2204 EFIS: 0212000073 QA Service Level: 1
DIST-CO-RTE-PM: 02-TRI-3-58.7/61.9
Work Description: REPLACE STRUCTURAL CONCRETE BRIDGE AND CULVERTS AND PLACE HMA.
Location Description: TRINITY COUNTY NEAR TRINITY CENTER FROM 58.7 MILES NORTH OF PREACHER MEADOWS ROAD TO 60.7 MILES SOUTH OF EL DORADO WAY
Contractor Name: MCCULLOUGH CONSTRUCTION INC
Contractor Address: 57 Alder Grove Road., Arcata, CA 95521
Resident Engineer: Mandhir Grewal Structure Rep.: Mike Sears

Sample Information

DIME Sample ID: 2022-09-14-52
TL Number from the TL Form: 857910
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/14/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/14/2022
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 16 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28 M) with 23.6% RAP and virgin PG 58-34 M from Valero (Benicia, CA)
From where was the sample collected: Manufacturer
Laboratory sample identification: D79157
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: J.F. Shea Construction – Fawndale Rock and Asphalt (Redding, CA)

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2022-09-14-52-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/30/2022
Date Tested: 09/14/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7335.8 grams
Mass of oven-dry sample in air for Sample 1 2580.8 grams
Mass of container filled with the sample and water for Sample 1 8901.9 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.543
Theoretical maximum density at 25°C (77°F) 158.3 lb/ft^3

Test 2 of 5

DIME Test ID: 2022-09-14-52-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/30/2022
Date Tested: 09/14/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.414
Bulk Specific Gravity 2 2.413
Bulk Specific Gravity 3 2.407
Average Bulk Specific Gravity 2.411

Test 3 of 5

DIME Test ID: 2022-09-14-52-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/30/2022
Date Tested: 09/14/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: VMA = 14.3%, VFA = 63.7%, DP = 1.0
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 5.1 %
Percent Air Voids 2 5.1 %
Percent Air Voids 3 5.3 %
Percent Air Voids Average 5.2 %

Test 4 of 5

DIME Test ID: 2022-09-14-52-4
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 09/30/2022
Date Tested: 09/19/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 129 psi
Average Wet Tensile Strength 120 psi
Tensile Strength Ratio 0.93

Test 5 of 5

DIME Test ID: 2022-09-14-52-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/30/2022
Date Tested: 09/20/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 4.65 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) 0.19 %
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data