Print Report | Back to Sample Detail

Sample Record for 2022-08-11-75

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993587 DEA: 061C3704 EFIS: 0621000163 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE,TUL-180,245-108.0/110.8,0.0/9.0
Work Description: COLD PLANE AC AND PLACE HMA (TYPE A).
Location Description: FRESNO AND TULARE COUNTIES ON ROUTE 180 FROM 0.1 MILE WEST OF ROUTE 245 TO 1.3 MILES EAST OF FRESNO COUNTY LINE AND ON ROUTE 245 FROM TULARE COUNTY LINE TO ?ROUTE 180
Contractor Name: Cal Valley Construction
Contractor Address: 5125 N. Gates Ave., Ste. 102, Fresno, CA, 93722-6414
Resident Engineer: Mark Mengoni Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-08-11-75
TL Number from the TL Form: C027127
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/11/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/09/2022
The quantity of what the sample constitutes: 4 Boxes
A brief description of the sample: 1/2 HMA Type A
From where was the sample collected: Job Site
Laboratory sample identification: 022-040
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Jaxon Baker Deer Creek

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number: 3
Sublot number: 8
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 3

DIME Test ID: 2022-08-11-75-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/20/2022
Date Tested: 09/13/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Method Performed no data
Mass of oven-dry sample in air for Sample 1 1574 grams
Mass of sample in water for Sample 1 988.2 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.687
Theoretical maximum density at 25°C (77°F) 167.3 lb/ft^3

Test 2 of 3

DIME Test ID: 2022-08-11-75-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/20/2022
Date Tested: 09/13/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2.571
Bulk Specific Gravity 2 2.573
Bulk Specific Gravity 3 2.579
Average Bulk Specific Gravity 2.574

Test 3 of 3

DIME Test ID: 2022-08-11-75-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/20/2022
Date Tested: 09/13/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 4.3 %
Percent Air Voids 2 4.2 %
Percent Air Voids 3 4 %
Average Percent Air Voids 4.2 %