Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993847 DEA: 081M8604 EFIS: 0822000056
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-180.2/186.2
Work Description: COLD PLANE AC PAVEMENT AND PLACE RUBBERIZED HMA (GAP GRADED).
Location Description: SAN BERNARDINO COUNTY ABOUT 43 MILES NORTH OF BAKER FROM 0.5 MILE SOUTH OF YATES WELL ROAD OVERCROSSING TO NEVADA STATE LINE
Contractor Name: LAS VEGAS PAVING CORPORATIO
Contractor Address: 4420 SOUTH DECATUR BLV, LAS VEGAS NEVADA 8910
Resident Engineer: KHOA NGUYEN Structure Rep.: Unknown
DIME Sample ID: 2022-09-08-21
TL Number from the TL Form: 01
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 09/08/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/09/2022
The quantity of what the sample constitutes: 2
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1046-01
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Las Vegs Paving Company-Las Vegas
The concrete mix design number: P40F023
The truck number from where the sample was collected: 1
The batch plant ticket number from where the sample was collected: NOT PROVIDED
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete Barrier Type 505D Footing
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-09-08-21-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap
Verified Date: 10/06/2022
Date Tested: 10/06/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Compressive strength (to nearest 10 psi)
|
5060 psi
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Compressive strength of cylinder 1
|
5042.2 psi
|
Compressive strength of cylinder 2
|
5077.2 psi
|
Maximum load on cylinder 1
|
63380 lb
|
Maximum load on cylinder 2
|
63820 lb
|
Type of fracture pattern of cylinder 1
|
1
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|