Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 04264724 Cty MRN Rte 101 PM R20.8/27.1 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Fabio La Serna |
Date Reported: |
09/16/2022 |
|
Address: |
TL Number: |
203181 |
||
City: |
||||
Project Name: CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL. |
||||
Prime Contractor: GHILOTTI CONSTRUCTION CO. INC. (RILEY GENAZZI & JOSH SERAFINO) |
||||
Sample Taken Date: |
09/02/2022 |
Mix Design: |
Unknown |
|
Contractor: Unknown |
Location : MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.01 | 12.63 | 69705 | 5519.0 | 2 |
2 | 4.00 | 12.57 | 67663 | 5384.0 | 4 |
3 | 4.03 | 12.76 | 73827 | 5788 | 4 |
DIME Test ID: 2022-09-02-43-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5560
Age of specimen: 14 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |