Project ID: 215682 DEA: 031H1904 EFIS: 0316000065
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-80,244-M9.6/12.9,0.0/T0.8
Work Description: COLD PLANE AC PAVEMENT, PLACE RHMA AND INDIVIDUAL SLAB REPLACEMENT.
Location Description: SACRAMENTO COUNTY IN AND NEAR SACRAMENTO ON ROUTE 80 FROM 0.2 MILE EAST OF LONGVIEW DRIVE OVERCROSSING TO 0.4 MILE EAST OF MADISON AVENUE OVERCROSSING AND ON ROUTE 244 FROM 0.3 MILE NORTH OF AUBURN BOULEVARD TO CONNECTOR TO ROUTE 80
Contractor Name: A. Teichert and Sons, Inc. DBA Teichert Construction
Contractor Address: 400 Sunrise Blvd., Roseville, CA 95661
Resident Engineer: Deyaedden Elghassein Structure Rep.: Unknown
DIME Sample ID: 2022-09-02-35
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: High Friction Surface Treatment
Sample Taken Date: 09/02/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/06/2022
The quantity of what the sample constitutes: 32 Totes
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification: 943123
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2022-09-02-35-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 03/29/2023
Date Tested: 09/22/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Gel time ASTM C881=25 mins.
Cure rate ASTM D1640=1.23 hrs.
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2022-09-02-35-2
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 03/29/2023
Date Tested: 09/15/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted vendor's results.
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
5
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.483 in
|
Sample 1 Ultimate strength
|
4175.9 psi
|
Sample 1 Thickness
|
0.16 in
|
Sample 1 Area
|
0.0773 in^2
|
Sample 1 Ultimate Strength Actual
|
322.8 lbs
|
Sample 1 percent elongation
|
66.12 %
|
Sample 1 Time
|
0 MM:SS
|
Sample 2 Width
|
0.483 in
|
Sample 2 Thickness
|
0.146 in
|
Sample 2 Area
|
0.0705 in^2
|
Sample 2 Ultimate strength
|
3819.9 psi
|
Sample 2 Ultimate Strength Actual
|
269.3 lbs
|
Sample 2 percent elongation
|
56.23 %
|
Sample 2 Time
|
0 MM:SS
|
Sample 3 Width
|
0.491 in
|
Sample 3 Thickness
|
0.134 in
|
Sample 3 Area
|
0.0658 in^2
|
Sample 3 Ultimate strength
|
3899.7 psi
|
Sample 3 Ultimate Strength Actual
|
256.6 lbs
|
Sample 3 percent elongation
|
58.84 %
|
Sample 3 Time
|
0 MM:SS
|
Sample 4 Width
|
0.491 in
|
Sample 4 Thickness
|
0.151 in
|
Sample 4 Area
|
0.0741 in^2
|
Sample 4 Ultimate strength
|
3973 psi
|
Sample 4 Ultimate Strength Actual
|
294.4 lbs
|
Sample 4 percent elongation
|
62.06 %
|
Sample 4 Time
|
0 MM:SS
|
Sample 5 Width
|
0.484 in
|
Sample 5 Thickness
|
0.151 in
|
Sample 5 Area
|
0.0731 in^2
|
Sample 5 Ultimate strength
|
4114.9 psi
|
Sample 5 Ultimate Strength Actual
|
300.8 lbs
|
Sample 5 percent elongation
|
65.22 %
|
Sample 5 Time
|
0 MM:SS
|
Ultimate Strength Average
|
3997 psi
|
Percent Elongation Average
|
62 %
|