Print Report | Back to Sample Detail

Sample Record for 2022-08-24-29

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993778 DEA: 042W5404 EFIS: 0421000234 QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN-101-4.0/4.6
Work Description: PLACE POLYESTER CONCRETE OVERLAY.
Location Description: MARIN COUNTY NEAR SAUSALITO FROM 0.7 MILE NORTH OF WALDO UNDERCROSSING TO 0.2 MILE SOUTH OF FRONTAGE ROAD
Contractor Name: GOLDEN STATE BRIDGE INC
Contractor Address: 3701 Mallard Dr., Benicia, CA 94510
Resident Engineer: Dawit Habteselassie Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-08-24-29
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 08/24/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/25/2022
The quantity of what the sample constitutes: 10 Tankers
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification: 943122
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia

Material Information

Mfg. Lot Number(s): 1425453
Batch number: 1425453
Mix number: 1425453

Test Results

Test 1 of 6

DIME Test ID: 2022-08-24-29-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 10/10/2022
Date Tested: 10/10/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Viscosity 107

Test 2 of 6

DIME Test ID: 2022-08-24-29-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 10/10/2022
Date Tested: 10/10/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 1.09

Test 3 of 6

DIME Test ID: 2022-08-24-29-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 10/10/2022
Date Tested: 10/10/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 6
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.49 in
Sample 1 Ultimate strength 25137.5 psi
Sample 1 Thickness 0.23 in
Sample 1 Area 0.1127 in^2
Sample 1 Ultimate Strength Actual 2833 lbs
Sample 1 percent elongation 53.6 %
Sample 1 Time 3 MM:SS
Sample 2 Width 0.489 in
Sample 2 Thickness 0.225 in
Sample 2 Area 0.11 in^2
Sample 2 Ultimate strength 25063.6 psi
Sample 2 Ultimate Strength Actual 2757 lbs
Sample 2 percent elongation 54.2 %
Sample 2 Time 3 MM:SS
Sample 3 Width 0.489 in
Sample 3 Thickness 0.241 in
Sample 3 Area 0.1178 in^2
Sample 3 Ultimate strength 25696.1 psi
Sample 3 Ultimate Strength Actual 3027 lbs
Sample 3 percent elongation 56.5 %
Sample 3 Time 4 MM:SS
Sample 4 Width 0.489 in
Sample 4 Thickness 0.225 in
Sample 4 Area 0.11 in^2
Sample 4 Ultimate strength 26863.6 psi
Sample 4 Ultimate Strength Actual 2955 lbs
Sample 4 percent elongation 53.8 %
Sample 4 Time 4 MM:SS
Sample 5 Width 0.488 in
Sample 5 Thickness 0.238 in
Sample 5 Area 0.1161 in^2
Sample 5 Ultimate strength 23316.1 psi
Sample 5 Ultimate Strength Actual 2707 lbs
Sample 5 percent elongation 42.8 %
Sample 5 Time 3 MM:SS
Sample 6 Width 0.49 in
Sample 6 Thickness 0.249 in
Sample 6 Area 0.122 in^2
Sample 6 Ultimate strength 22967.2 psi
Sample 6 Ultimate Strength Actual 2802 lbs
Sample 6 percent elongation 42.8 %
Sample 6 Time 3 MM:SS
Ultimate Strength Average 24841 psi
Percent Elongation Average 51 %

Test 4 of 6

DIME Test ID: 2022-08-24-29-4
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 10/10/2022
Date Tested: 10/10/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Diameter of lid 155.45 mm
Room Temperature 76 f
Tare weight no data
Initial weight 100.05 grams
Weight at 5 minutes 99.97 grams
Weight at 10 minutes 99.9 grams
Weight at 15 minutes 99.82 grams
Weight at 20 minutes 99.75 grams
Weight at 25 minutes 99.68 grams
Weight at 30 minutes 99.61 grams
Final weight 99.61 grams
Total weight loss 0.44 grams
Calculated radius of gallon can lid in cm 7.773 cm
Lid Factor 52.683 m^2
Volatile emission 23.181 grams/m^2

Test 5 of 6

DIME Test ID: 2022-08-24-29-5
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 10/10/2022
Date Tested: 10/10/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Mean of two volatile content determination 45

Test 6 of 6

DIME Test ID: 2022-08-24-29-6
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 10/10/2022
Date Tested: 10/10/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: *Accepted based on supplier results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 1433 lb
Span length for Sample 1 9 in
Break location for Sample 1 bond
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 716.53 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 1324 lb
Span length for Sample 2 9 in
Break location for Sample 2 bond
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 662.28 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1513 lb
Span length for Sample 3 9 in
Break location for Sample 3 bond
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 756.84 psi