Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993603 DEA: 051N7004 EFIS: 0521000081
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-166-16.0/21.0
Work Description: PARTIAL DEPTH RECYCLING AND OVERLAY WITH RHMA (GAP GRADED).
Location Description: SAN LUIS OBISPO COUNTY ABOUT 8 MILES EAST OF SANTA MARIA FROM 0.5 MILE WEST OF HUASNA RIVER BRIDGE TO 1.9 MILES WEST OF CUYAMA RIVER BRIDGE.
Contractor Name: PAPICH CONSTRUCTION COMPANY INC.
Contractor Address: Unknown
Resident Engineer: Thomas Petersen Structure Rep.: Unknown
DIME Sample ID: 2022-08-23-47
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Sample Organization Contact:
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/23/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/23/2022
The quantity of what the sample constitutes: L1SL3
A brief description of the sample: 3/4" RHMA-G
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Papich Templeton
DIME Test ID: 2022-08-23-47-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/02/2022
Date Tested: 09/02/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Water
|
Specific Gravity for Sample 1
|
2.382
|
Theoretical maximum density at 25°C (77°F)
|
148.7 lb/ft^3
|
DIME Test ID: 2022-08-23-47-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/02/2022
Date Tested: 08/24/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity
|
2.242
|
Bulk Specific Gravity 2
|
2.238
|
Bulk Specific Gravity 3
|
2.189
|
Average Bulk Specific Gravity
|
2.223
|
DIME Test ID: 2022-08-23-47-3
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 09/02/2022
Date Tested: 08/23/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test: Report only
Test Result Compliance: not applicable
Additional Comments When Verified:
What type of gradation is being tested?
|
HMA Gradation
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
99.8 %
|
Cumulative percent passing the 1/2 in. sieve
|
84.5 %
|
Cumulative percent passing the 3/8 in. sieve
|
67.8 %
|
Cumulative percent passing the #4 sieve
|
33.8 %
|
Cumulative percent passing the #8 sieve
|
57 %
|
Cumulative percent passing the #16 sieve
|
34.1 %
|
Cumulative percent passing the #30 sieve
|
19.8 %
|
Cumulative percent passing the #50 sieve
|
11.8 %
|
Cumulative percent passing the #100 sieve
|
7.8 %
|
Cumulative percent passing the #200 sieve
|
5.4 %
|
DIME Test ID: 2022-08-23-47-4
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 10/06/2022
Date Tested: 10/06/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Dispute resolution testing
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used?
|
No
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
99 %
|
Cumulative percent passing the 1/2 in. sieve
|
85 %
|
Cumulative percent passing the 3/8 in. sieve
|
65 %
|
Cumulative percent passing the #4 sieve
|
31 %
|
Cumulative percent passing the #8 sieve
|
17 %
|
Cumulative percent passing the #16 sieve
|
10 %
|
Cumulative percent passing the #30 sieve
|
7 %
|
Cumulative percent passing the #50 sieve
|
5 %
|
Cumulative percent passing the #100 sieve
|
4 %
|
Cumulative percent passing the #200 sieve
|
2.5 %
|
DIME Test ID: 2022-08-23-47-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/06/2022
Date Tested: 10/06/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Dispute resolution testing
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
no data
|
Mass of HMA Sample prior to ignition
|
no data
|
Corrected Asphalt Binder Content
|
7.68 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
1.1 %
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|