Print Report | Back to Sample Detail

Sample Record for 2022-08-23-47

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993603 DEA: 051N7004 EFIS: 0521000081 QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-166-16.0/21.0
Work Description: PARTIAL DEPTH RECYCLING AND OVERLAY WITH RHMA (GAP GRADED).
Location Description: SAN LUIS OBISPO COUNTY ABOUT 8 MILES EAST OF SANTA MARIA FROM 0.5 MILE WEST OF HUASNA RIVER BRIDGE TO 1.9 MILES WEST OF CUYAMA RIVER BRIDGE.
Contractor Name: PAPICH CONSTRUCTION COMPANY INC.
Contractor Address: Unknown
Resident Engineer: Thomas Petersen Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-08-23-47
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Sample Organization Contact:
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/23/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/23/2022
The quantity of what the sample constitutes: L1SL3
A brief description of the sample: 3/4" RHMA-G
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Papich Templeton

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number: 1
Sublot number: 3
HMA Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2022-08-23-47-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/02/2022
Date Tested: 09/02/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Specific Gravity for Sample 1 2.382
Theoretical maximum density at 25°C (77°F) 148.7 lb/ft^3

Test 2 of 5

DIME Test ID: 2022-08-23-47-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/02/2022
Date Tested: 08/24/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity 2.242
Bulk Specific Gravity 2 2.238
Bulk Specific Gravity 3 2.189
Average Bulk Specific Gravity 2.223

Test 3 of 5

DIME Test ID: 2022-08-23-47-3
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 09/02/2022
Date Tested: 08/23/2022
Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Organization Address: 2053 Preisker Lane, Suite E,
Organization City: Santa Maria
Organization State: CA
Organization Zipcode: 93427
Organization Email: salvador.lopez-zamora@dot.ca.gov
Organization Phone: (805) 748-3854
General Comments for this Test: Report only
Test Result Compliance: not applicable
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 99.8 %
Cumulative percent passing the 1/2 in. sieve 84.5 %
Cumulative percent passing the 3/8 in. sieve 67.8 %
Cumulative percent passing the #4 sieve 33.8 %
Cumulative percent passing the #8 sieve 57 %
Cumulative percent passing the #16 sieve 34.1 %
Cumulative percent passing the #30 sieve 19.8 %
Cumulative percent passing the #50 sieve 11.8 %
Cumulative percent passing the #100 sieve 7.8 %
Cumulative percent passing the #200 sieve 5.4 %

Test 4 of 5

DIME Test ID: 2022-08-23-47-4
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 10/06/2022
Date Tested: 10/06/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Dispute resolution testing
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 99 %
Cumulative percent passing the 1/2 in. sieve 85 %
Cumulative percent passing the 3/8 in. sieve 65 %
Cumulative percent passing the #4 sieve 31 %
Cumulative percent passing the #8 sieve 17 %
Cumulative percent passing the #16 sieve 10 %
Cumulative percent passing the #30 sieve 7 %
Cumulative percent passing the #50 sieve 5 %
Cumulative percent passing the #100 sieve 4 %
Cumulative percent passing the #200 sieve 2.5 %

Test 5 of 5

DIME Test ID: 2022-08-23-47-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/06/2022
Date Tested: 10/06/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Dispute resolution testing
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 7.68 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) 1.1 %
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data