Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676
QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-80-R10.4/30.2
Work Description: Highway widening, overhead signs, and electronic toll system.
Location Description: In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
Contractor Name: O.C. JONES & SONS, INC.
Contractor Address: 1520 Fourth Street, Berkeley, CA 94710
Resident Engineer: Justen Tatum Structure Rep.: Kelsey Littell
DIME Sample ID: 2022-08-23-31
TL Number from the TL Form:
Sample Submitted By Organization: Con-Fab California, LLC
Sample Organization Contact: (661) 630-7162
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/23/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/24/2022
The quantity of what the sample constitutes: One Girder
A brief description of the sample: PCC 4''X8'' Test Cylinder
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Con-Fab California, LLC
The concrete mix design number: SCCS9015F
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 2686
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Casting Bed Alpha East
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-08-23-31-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 09/07/2022
Date Tested: 08/23/2022
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2022-08-23-31-2
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 09/07/2022
Date Tested: 08/23/2022
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2022-08-23-31-3
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 09/07/2022
Date Tested: 08/23/2022
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Identification of concrete represented by the sample
|
Girder
|
|
Volume of the measure
|
0.25 ft^3
|
|
Density of concrete
|
149.8 lb/ft^3
|
|
Yield of concrete
|
no data
|
|
Relative yield of the batch
|
no data
|
|
Cement content
|
no data
|
|
Air content
|
no data
|
DIME Test ID: 2022-08-23-31-4
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 09/07/2022
Date Tested: 08/23/2022
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2022-08-23-31-5
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/07/2022
Date Tested: 08/24/2022
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
no data
|
|
Apparent mass of submerged cylinder 1
|
8.9 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.5 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5460 psi
|
|
Maximum load on cylinder 1
|
70185 lb
|
|
Maximum load on cylinder 2
|
67065 lb
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Type of fracture pattern of cylinder 2
|
5
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
no data0 days
|
|
Age of specimen in hours
|
21 hours
|
|
Serial number of delivery ticket, if available
|
no data
|
DIME Test ID: 2022-08-23-31-6
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Verified Date: 09/07/2022
Date Tested: 08/23/2022
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Precast Maximum Curing Temperature
|
145.2 °F
|
DIME Test ID: 2022-08-23-31-7
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/07/2022
Date Tested: 08/30/2022
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
no data
|
|
Apparent mass of submerged cylinder 1
|
8.9 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
6670 psi
|
|
Maximum load on cylinder 1
|
82685 lb
|
|
Maximum load on cylinder 2
|
83995 lb
|
|
Maximum load on cylinder 3
|
84745 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
5
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|