Print Report | Back to Sample Detail

Sample Record for 2022-06-15-67

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-06-15-67
TL Number from the TL Form:
Sample Submitted By Organization: Pyramid Construction and Aggregates
Sample Organization Contact: (760) 337-5839
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 06/15/2022
Date that the sample was received by the laboratory/organization performing the testing: 06/16/2022
The quantity of what the sample constitutes: Good
A brief description of the sample: 3/8"
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pyramid Construction

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-13-0095
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Stockpile
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/8 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2022-06-15-67-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 08/23/2022
Date Tested: 08/22/2022
Submitted By Organization: Pyramid Construction and Aggregates
Organization Address: 839 Dogwood Road,
Organization City: Heber
Organization State: CA
Organization Zipcode: 92249
Organization Email: archie@pyramidca.com
Organization Phone: (760) 337-5839
General Comments for this Test: Submitted from JMF - Archie Abeyta
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 2 in. sieve no data
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 88 %
Cumulative percent passing the #4 sieve 5 %
Cumulative percent passing the #8 sieve 1 %
Cumulative percent passing the #16 sieve 0.5 %
Cumulative percent passing the #30 sieve no data0 %
Cumulative percent passing the #50 sieve no data0 %
Cumulative percent passing the #100 sieve no data0 %
Cumulative percent passing the #200 sieve no data0 %