Print Report | Back to Sample Detail

Sample Record for 2022-08-10-27

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993235 DEA: 051H4504 EFIS: 0516000075 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-154-R31.8/R32.1
Work Description: CONSTRUCT CIDH CONCRETE PILES AND STRUCTURAL CONCRETE BRIDGE.
Location Description: SANTA BARBARA COUNTY IN AND NEAR SANTA BARBARA FROM PRIMAVERA ROAD UNDERCROSSING TO LA COLINA ROAD UNDERCROSSING
Contractor Name: CA Rasmussen
Contractor Address: 28548 LIVINGSTON AVENUE, VALENICA CA 91355
Resident Engineer: Jeffery Finn Structure Rep.: Emiliano Berntsen

Sample Information

DIME Sample ID: 2022-08-10-27
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 08/10/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/12/2022
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber Corp

Material Information

Mfg. Lot Number(s): 21180-4
Material/Compound/Elastomer ID: NA
Samples Representing: 1
Description (size): 1.5"x18"x24"
Comments:
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2022-08-10-27-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 08/22/2022
Date Tested: 08/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 52
Reading #2 52
Reading #3 52
Reading #4 50
Reading #5 52
Mean 51.6

Test 2 of 4

DIME Test ID: 2022-08-10-27-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 08/22/2022
Date Tested: 08/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 5
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.061
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2442.43 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.072
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2437.77 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.063
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2225.05 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Sample 4 Median Thickness 0.062
Sample 4 Thickness all Within 0.003 inch? Yes
Sample 4 Ultimate Tensile 2523.24 lbf/in^2
Sample 4 Elongation (350% Min) Pass
Sample 5 Median Thickness 0.058
Sample 5 Thickness all Within 0.003 inch? Yes
Sample 5 Ultimate Tensile 2415.8 lbf/in^2
Sample 5 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2437.8 lbf/in^2

Test 3 of 4

DIME Test ID: 2022-08-10-27-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 08/22/2022
Date Tested: 08/17/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.062
Sample 1 Tear Strength 214.4
Sample 2 Median Thickness 0.062
Sample 2 Tear Strength 288.4
Sample 3 Median Thickness 0.062
Sample 3 Tear Strength 309.9
Median of the Tear Strength Values 288.4 lb/in

Test 4 of 4

DIME Test ID: 2022-08-10-27-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 08/18/2022
Date Tested: 08/18/2022
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass