Sample Record for 2022-08-16-10
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993771 DEA: 07325204 EFIS: 0716000082
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R36.7/R37.1
Work Description: San Gabriel River Bridge - CM/GC Project - Hinge And Diaphragm Repairs
Location Description: Los Angeles County - LOS ANGELES COUNTY IN IRWINDALE FROM 0.2 MILE EAST OF 0.7 MILE WEST OF IRWINDALE AVENUE OVECROSSING
Contractor Name: FLATIRON WEST INC
Contractor Address: 14726 Ramona Avenue, Suite 300, Chino, CA 91710
Resident Engineer: Moe Izadpanah Structure Rep.: Quynh Nguyen
Sample Information
DIME Sample ID: 2022-08-16-10
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 08/16/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/19/2022
The quantity of what the sample constitutes: 8 Headed bars from lots 1-2
A brief description of the sample: #11 HRC 555 Headed Bars
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific Steel Group
Material Information
Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 1201041289
Head Manufacturer Lot Number(s): Lots 1-2
Rebar Size: #11
Headed Bar Model Name: HRC 555 Round Headed Bars
Size of Head: Full Size - 9x
Head Connection Type: Forged
Head Shape: Circular
Rebar Manufacturer: Nucor
Head Manufacturer: HRC Pacific Steel Group
Head Fabricator: Pacific Steel Group
Material Standard Code: ASTM A706
Headed Bar Unique ID:
Test Results
Test 1 of 6
DIME Test ID: 2022-08-16-10-1
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 08/18/2022
Date Tested: 08/18/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: ok necking
Test Result Compliance:
Additional Comments When Verified:
|
Number of Headed Bar Samples
|
1
|
| Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | | 1 | 1.56 | 142221.23 | 91167 | ok necking | spaine |
| |
|
Temperature
|
72 f
|
|
UTM
|
450kip
|
Test 2 of 6
DIME Test ID: 2022-08-16-10-2
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 08/18/2022
Date Tested: 08/18/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: ok necking
Test Result Compliance:
Additional Comments When Verified:
|
Number of Headed Bar Samples
|
1
|
| Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | | 1 | 1.56 | 140035.42 | 89766 | ok necking | spaine |
| |
|
Temperature
|
72 f
|
|
UTM
|
450kip
|
Test 3 of 6
DIME Test ID: 2022-08-16-10-3
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 08/18/2022
Date Tested: 08/18/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: ok necking
Test Result Compliance:
Additional Comments When Verified:
|
Number of Headed Bar Samples
|
1
|
| Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | | 1 | 1.56 | 144106.72 | 92376 | ok necking | spaine |
| |
|
Temperature
|
72 f
|
|
UTM
|
450kip
|
Test 4 of 6
DIME Test ID: 2022-08-16-10-4
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 08/18/2022
Date Tested: 08/18/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: ok necking
Test Result Compliance:
Additional Comments When Verified:
|
Number of Headed Bar Samples
|
1
|
| Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | | 2 | 1.56 | 143085.55 | 91722 | ok necking | spaine |
| |
|
Temperature
|
72 f
|
|
UTM
|
450kip
|
Test 5 of 6
DIME Test ID: 2022-08-16-10-5
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 08/18/2022
Date Tested: 08/18/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: ok necking
Test Result Compliance:
Additional Comments When Verified:
|
Number of Headed Bar Samples
|
1
|
| Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | | 2 | 1.56 | 143927.04 | 92261 | ok necking | spaine |
| |
|
Temperature
|
72 f
|
|
UTM
|
450kip
|
Test 6 of 6
DIME Test ID: 2022-08-16-10-6
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 08/18/2022
Date Tested: 08/18/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: ok necking
Test Result Compliance:
Additional Comments When Verified:
|
Number of Headed Bar Samples
|
1
|
| Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | | 2 | 1.56 | 144021.04 | 92321 | ok necking | spaine |
| |
|
Temperature
|
72 f
|
|
UTM
|
450kip
|