Print Report | Back to Sample Detail

Sample Record for 2022-08-09-24

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993771 DEA: 07325204 EFIS: 0716000082 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R36.7/R37.1
Work Description: San Gabriel River Bridge - CM/GC Project - Hinge And Diaphragm Repairs
Location Description: Los Angeles County - LOS ANGELES COUNTY IN IRWINDALE FROM 0.2 MILE EAST OF 0.7 MILE WEST OF IRWINDALE AVENUE OVECROSSING
Contractor Name: FLATIRON WEST INC
Contractor Address: 14726 Ramona Avenue, Suite 300, Chino, CA 91710
Resident Engineer: Moe Izadpanah Structure Rep.: Quynh Nguyen

Sample Information

DIME Sample ID: 2022-08-09-24
TL Number from the TL Form:
Sample Submitted By Organization: CT METS QASI - Los Angeles Design Build Field Laboratory
Sample Organization Contact: (619) 204-7248
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 08/09/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/15/2022
The quantity of what the sample constitutes: 2 Couplers
A brief description of the sample: Double Barrel Zap Screwlok
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 53-1867
Structure name: San Gabriel River Bridge
The fabricator/manufacturer/facility name: Pacific Steel Group

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Nucor
Coupler Manufacturer: BarSplice
Intermediate Assembler or Fabricator:
Rebar Size: #6
Coupler Model: Double Barrel Zap Screwlok
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): 1239
Rebar Heat Number(s): 3500026529
Rebar Size 2 :
Coupler Unique ID:

Test Results

Test 1 of 2

DIME Test ID: 2022-08-09-24-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Verified Date: 08/17/2022
Date Tested: 08/16/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: service splice, broke in old bar
Test Result Compliance:
Additional Comments When Verified:
Number of Samples Tested 1
SampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1No. 6/19mm100.443271874360service splice, broke in old barspaine
UTM 450kip
Temperature 72.00 f
Halo ID

Test 2 of 2

DIME Test ID: 2022-08-09-24-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Verified Date: 08/17/2022
Date Tested: 08/16/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: service splice, broke in old bar
Test Result Compliance:
Additional Comments When Verified:
Number of Samples Tested 1
SampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
2No. 6/19mm100.443411477531service splice, broke in old barspaine
UTM 450kip
Temperature 72.00 f
Halo ID