Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214524 DEA: 07304504 EFIS: 0714000067
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-57-R0.0/R4.5
Work Description: CONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK.
Location Description: LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION
Contractor Name: Griffith Company
Contractor Address: 3050 E. Birch Street, Brea, CA 92821
Resident Engineer: Martin Sandoval Structure Rep.: Avtar Bains
DIME Sample ID: 2022-07-25-50
TL Number from the TL Form:
Sample Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Sample Organization Contact: (909) 833-5780
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/25/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/25/2022
The quantity of what the sample constitutes: Approx 2000 CY
A brief description of the sample: A set of 2 CRCP concrete beam test specimens
From where was the sample collected: Job Site
Laboratory sample identification: 22-1915
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard at the 57 Freeway
The concrete mix design number: 57030SL
The truck number from where the sample was collected: Load 33
The batch plant ticket number from where the sample was collected: 10987
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-07-25-50-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 08/25/2022
Date Tested: 08/22/2022
Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Organization Address: 620 South Magnolia Avenue, Building G,
Organization City: Ontario
Organization State: CA
Organization Zipcode: 91762
Organization Email: mdorsch@kleinfelder.com
Organization Phone: (909) 833-5780
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of specimens
|
2
|
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
|
Fracture occurred at a capped section
|
No
|
|
Is a beam dimensional correction factor used?
|
No
|
|
Age of specimen
|
28 days
|
|
Modulus of rupture
|
760 psi
|
|
Modulus of rupture 2
|
810 psi
|
|
Modulus of rupture average
|
785 psi
|