Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 033F0734 Cty SAC Rte 51 PM 2.0/3.5 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
John Ruzic |
Date Reported: |
05/31/2024 |
|
|
Address: |
TL Number: |
225327 |
||
|
City: |
||||
|
Project Name: Dredge, construct in-water foundation |
||||
|
Prime Contractor: American River Constructors |
||||
|
Sample Taken Date: |
08/02/2022 |
Mix Design: |
1615453 |
|
|
Contractor: Unknown |
Location : |
|||
|
Structure unique identifier: |
||||
|
Structure name: |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.02 | 12.69 | 46543 | 3667.0 | 4 |
| 2 | 4.02 | 12.69 | 47704 | 3758.0 | 1 |
| 3 | 4.02 | 12.69 | 43245 | 3407 | 1 |
DIME Test ID: 2022-08-02-23-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3610
Age of specimen: 7 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.03 | 12.76 | 49810 | 3905.0 | 4 |
| 2 | 4.02 | 12.69 | 53666 | 4228.0 | 2 |
| 3 | 4.02 | 12.69 | 52202 | 4113 | 1 |
DIME Test ID: 2022-08-02-23-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4080
Age of specimen: 14 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.03 | 12.76 | 58272 | 4568.0 | 2 |
| 2 | 4.03 | 12.76 | 57698 | 4523.0 | 2 |
| 3 | 4.04 | 12.82 | 53791 | 4196 | 2 |
DIME Test ID: 2022-08-02-23-3
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4430
Age of specimen: 21 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.04 | 12.82 | 64037 | 4996.0 | 2 |
| 2 | 4.05 | 12.88 | 60498 | 23481.0 | 2 |
| 3 | 4.03 | 12.76 | 55933 | 4385 | 4 |
DIME Test ID: 2022-08-02-23-4
Number of specimens: 3
Compressive strength (to nearest 10 psi): 10950
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.04 | 12.82 | 64037 | 4996.0 | 2 |
| 2 | 4.05 | 12.88 | 60498 | 4697.0 | 2 |
| 3 | 4.03 | 12.76 | 55933 | 4385 | 4 |
DIME Test ID: 2022-08-02-23-5
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4690
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 28 days
Certified By: Phillip Montes
Test ID: 2022-08-02-23-5: Corrected an error in specimen 2 correction factor - SA
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing