Print Report | Back to Sample Detail

Sample Record for 2022-07-28-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212085 DEA: 07296604 EFIS: 0713000057 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-14.0/19.0
Work Description: PAINT AND REHABILITATE BRIDGE - (STRAIN (PAINT AND INSTALL CATWALK)
Location Description: IN THE CITY OF LOS ANGELES, AT SANTA MONICA VIADUCT (BR. NO. 53-1301). PAINT AND REHABILITATE BRIDGE
Contractor Name: CL Industrial Coating Inc.
Contractor Address: 11650 Western Ave., Stanton, CA 90680
Resident Engineer: Susana Facio Structure Rep.: Nabil Shmara

Sample Information

DIME Sample ID: 2022-07-28-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/28/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/03/2022
The quantity of what the sample constitutes: 555
A brief description of the sample: ASTM A325 TC Bolt Assembly
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Page Industrial

Material Information

Rocap Number(s): 36500-1000216027
Heat Number(s):
Nut Mfg. Lot Number(s): 36256-223185
Washer Mfg. Lot Number(s): 1221-163
Bolt Specification: ASTM A3125-F1852
Bolt Length(s): 2"
Nut Specification: A563 DH
Washer Specification: F436
Finish: Mechanical Galv.
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: 36500-1000216027
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 35

DIME Test ID: 2022-07-28-2-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 08/16/2022
Date Tested: 08/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1A52803Nut Proof Load
UTM 450kip
Temperature 72 f

Test 2 of 35

DIME Test ID: 2022-07-28-2-2
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 08/16/2022
Date Tested: 08/10/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1B52816Nut Proof Load
UTM 450kip
Temperature 72 f

Test 3 of 35

DIME Test ID: 2022-07-28-2-3
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Gage Type Pass

Test 4 of 35

DIME Test ID: 2022-07-28-2-4
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Gage Type Pass

Test 5 of 35

DIME Test ID: 2022-07-28-2-5
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Gage Type Pass

Test 6 of 35

DIME Test ID: 2022-07-28-2-6
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Gage Type Pass

Test 7 of 35

DIME Test ID: 2022-07-28-2-7
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Gage Type Pass

Test 8 of 35

DIME Test ID: 2022-07-28-2-8
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Gage Type Pass

Test 9 of 35

DIME Test ID: 2022-07-28-2-9
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Gage Type Pass

Test 10 of 35

DIME Test ID: 2022-07-28-2-10
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Gage Type Pass

Test 11 of 35

DIME Test ID: 2022-07-28-2-11
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Gage Type Pass

Test 12 of 35

DIME Test ID: 2022-07-28-2-12
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Gage Type Pass

Test 13 of 35

DIME Test ID: 2022-07-28-2-13
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Measurement Average 3.23 mils

Test 14 of 35

DIME Test ID: 2022-07-28-2-14
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Measurement Average 4.03 mils

Test 15 of 35

DIME Test ID: 2022-07-28-2-15
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Measurement Average 4.29 mils

Test 16 of 35

DIME Test ID: 2022-07-28-2-16
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Measurement Average 3.34 mils

Test 17 of 35

DIME Test ID: 2022-07-28-2-17
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Measurement Average 4 mils

Test 18 of 35

DIME Test ID: 2022-07-28-2-18
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Bolt Length no data in
Measurement Average 3.59 mils

Test 19 of 35

DIME Test ID: 2022-07-28-2-19
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Bolt Length no data in
Measurement Average 2.86 mils

Test 20 of 35

DIME Test ID: 2022-07-28-2-20
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Bolt Length no data in
Measurement Average 3.93 mils

Test 21 of 35

DIME Test ID: 2022-07-28-2-21
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Bolt Length no data in
Measurement Average 3.44 mils

Test 22 of 35

DIME Test ID: 2022-07-28-2-22
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Bolt Length no data in
Measurement Average 2.9 mils

Test 23 of 35

DIME Test ID: 2022-07-28-2-23
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 1221-163
Finish Coating ASTM B695 - Mech Galv
Product Markings F436 P
Size .75 in
Bolt Length no data in
Measurement Average 2.79 mils

Test 24 of 35

DIME Test ID: 2022-07-28-2-24
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 1221-163
Finish Coating ASTM B695 - Mech Galv
Product Markings F436 P
Size .75 in
Bolt Length no data in
Measurement Average 3.4 mils

Test 25 of 35

DIME Test ID: 2022-07-28-2-25
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 1221-163
Finish Coating ASTM B695 - Mech Galv
Product Markings F436 P
Size .75 in
Bolt Length no data in
Measurement Average 3.17 mils

Test 26 of 35

DIME Test ID: 2022-07-28-2-26
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 1221-163
Finish Coating ASTM B695 - Mech Galv
Product Markings F436 P
Size .75 in
Bolt Length no data in
Measurement Average 3.04 mils

Test 27 of 35

DIME Test ID: 2022-07-28-2-27
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 1221-163
Finish Coating ASTM B695 - Mech Galv
Product Markings F436 P
Size .75 in
Bolt Length no data in
Measurement Average 3.07 mils

Test 28 of 35

DIME Test ID: 2022-07-28-2-28
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Hardness Reading Scale C Scale
Hardness Reading Average 32.9
Spacing Ok

Test 29 of 35

DIME Test ID: 2022-07-28-2-29
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Hardness Reading Scale C Scale
Hardness Reading Average 32.1
Spacing Ok

Test 30 of 35

DIME Test ID: 2022-07-28-2-30
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36500-1000216027
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size .75 in
Bolt Length 2 in
Hardness Reading Scale C Scale
Hardness Reading Average 32.02
Spacing Ok

Test 31 of 35

DIME Test ID: 2022-07-28-2-31
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 52803
Spacing no data

Test 32 of 35

DIME Test ID: 2022-07-28-2-32
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 36256-223185
Finish Coating ASTM B695 - Mech Galv
Product Markings DH U
Size .75 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 52816
Spacing no data

Test 33 of 35

DIME Test ID: 2022-07-28-2-33
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 1221-163
Finish Coating ASTM B695 - Mech Galv
Product Markings F436 P
Size .75 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 38.8
Spacing Ok

Test 34 of 35

DIME Test ID: 2022-07-28-2-34
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 1221-163
Finish Coating ASTM B695 - Mech Galv
Product Markings F436 P
Size .75 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 38.53
Spacing Ok

Test 35 of 35

DIME Test ID: 2022-07-28-2-35
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/16/2022
Date Tested: 08/11/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 1221-163
Finish Coating ASTM B695 - Mech Galv
Product Markings F436 P
Size .75 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 39.73
Spacing Ok