Sample Record for 2021-11-03-55
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 215236 DEA: 081C6804 EFIS: 0812000343
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74,79and371-Varies
Work Description: REPLACE STRUCTURAL CONCRETE BRIDGE, RETAINING WALL AND BOX CULVERT.
Location Description: RIVERSIDE COUNTY AT VARIOUS LOCATIONS
Contractor Name: Ortiz Enterprise
Contractor Address: 6 Cushing, Suite 200, Irvine, Ca 92618-4221
Resident Engineer: Nick Truong Structure Rep.: Arnel L. Vega
Sample Information
DIME Sample ID: 2021-11-03-55
TL Number from the TL Form:
Sample Submitted By Organization: Sequoia Consultants
Sample Organization Contact: (714) 974-6316
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 11/03/2021
Date that the sample was received by the laboratory/organization performing the testing: 11/03/2021
The quantity of what the sample constitutes: 2 cylinders
A brief description of the sample: PCC
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex Perris
Material Information
The concrete mix design number: 91-36-0040
The truck number from where the sample was collected: 7848
The batch plant ticket number from where the sample was collected: 29936388
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Blue Ridge Wash RCB
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 2
DIME Test ID: 2021-11-03-55-1
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/14/2022
Date Tested: 12/01/2021
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
2
|
Average Compressive Strength (to nearest 10)
|
5470 lb/in^2
|
Cylinder Age
|
28 days
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
Break Description of Cylinder 2 (if not 'cone')
|
no data
|
Test 2 of 2
DIME Test ID: 2021-11-03-55-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/14/2022
Date Tested: 12/12/2021
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
5270 psi
|
Maximum load on cylinder 1
|
149820 lb
|
Maximum load on cylinder 2
|
148260 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data0 hours
|