Print Report | Back to Sample Detail

Sample Record for 2022-07-11-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-07-11-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Quality Control
Type of Material: Asphalt Modifier
Sample Taken Date: 07/11/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/11/2022
The quantity of what the sample constitutes: 24 Boxes
A brief description of the sample: 3/4 inch RHMA-G PG 64-16
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Syar Industries - Lake Herman

Material Information

Asphalt Modifier Type: Tricor Refining
Asphalt Modifier Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2022-07-11-9-1
Test Method: ASTM D445-14: Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) (Kinematic Viscosity)
Verified Date: 07/11/2022
Date Tested: 07/11/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Submitted from JMF - James Brewster
Test Result Compliance:
Additional Comments When Verified:
First Kinematic Viscosity no data
Second Kinematic Viscosity no data
Kinematic Viscosity 22.0000 m2/s
Dynamic Viscosity no data

Test 2 of 3

DIME Test ID: 2022-07-11-9-2
Test Method: ASTM D92-12b: Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester (Flash Point)
Verified Date: 07/11/2022
Date Tested: 07/11/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Submitted from JMF - James Brewster
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Ambient Barometric Pressure unit? mm Hg
Corrected Flash Point 2 C

Test 3 of 3

DIME Test ID: 2022-07-11-9-3
Test Method: ASTM D2007-11: Standard Test Method for Characteristic Groups in Rubber Extender and Processing Oils and Other Petroleum-Derived Oils by the Clay-Gel Absorption Chromatographic Method (Clay Gel Absorption)
Verified Date: 07/11/2022
Date Tested: 07/11/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Submitted from JMF - James Brewster
Test Result Compliance:
Additional Comments When Verified:
Method of determination of aromatic content: Difference
Asphaltenes, percent by mass no data
Aromatics, percent by mass 65.0 %