Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214493 DEA: 07311704 EFIS: 0715000013
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-134-0.0/R13.3
Work Description: CONCRETE SLAB REPLACEMENT, HMA PAVING, ELECTRICAL AND LANDSCAPE WORK.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES, BURBANK, GLENDALE AND PASADENA FROM ROUTE 101/134 SEPARATION TO JUNCTION OF ROUTE 210/710
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 16351 Construction Circle West, Irvine, CA 92606-4414
Resident Engineer: David Ayala Vanegas Structure Rep.: Unknown
DIME Sample ID: 2022-06-21-47
TL Number from the TL Form: C924190
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Department Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 06/21/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/06/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: PG Asphalt Binder
From where was the sample collected: Supplier
Laboratory sample identification: C924190
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Irwindale
Performance Grade: PG 64-10
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2022-06-21-47-1
Test Method: AASHTO T228-09r13: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2022-06-21-47-2
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: -0.061+0.006=-.055
Test Result Compliance: complies
Additional Comments When Verified:
|
Is mass change based on one or two containers?
|
Two
|
|
Any material loss from containers during heating process/testing?
|
No
|
|
Mass of empty container #1
|
169.583 grams
|
|
Mass of empty container #2
|
167.31 grams
|
|
Mass of container #1 before test (m1i)
|
204.705 grams
|
|
Mass of container #2 before test (m2i)
|
202.16 grams
|
|
Mass of container #1 after test (m1f)
|
204.684 grams
|
|
Mass of container #2 after test (m2f)
|
202.138 grams
|
|
Average mass change
|
-0.061 percent
|
DIME Test ID: 2022-06-21-47-3
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
Original binder
|
|
Phase Angle (δ) (for the 10 cycles)
|
87.1 degree
|
|
Dynamic Shear, G*/sin(δ)
|
1.53 kPa
|
|
(G*) x sin(δ)=
|
no data
|
DIME Test ID: 2022-06-21-47-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: RTFO Aged DSR
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
RTFO residue
|
|
Test Plate Diameter
|
25 mm
|
|
Phase Angle (δ) (for the 10 cycles)
|
83.7 degree
|
|
Dynamic Shear, G*/sin(δ)
|
4.24 kPa
|
DIME Test ID: 2022-06-21-47-5
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
|
Time of test
|
9:25 HH:MM
|
|
Test Temperature
|
135 C
|
|
Speed
|
100 rpm
|
|
Spindle size
|
21 in
|
|
Torque
|
83 %
|
|
Viscosity reading #1 (A)
|
0.415 Pa-s
|
|
Viscosity reading #2 (B)
|
0.42 Pa-s
|
|
Viscosity reading #3 (C)
|
0.419 Pa-s
|
|
Average viscosity
|
0.418 Pa-s
|
DIME Test ID: 2022-06-21-47-6
Test Method: AASHTO T44-18: Standard Method of Test for Solubility of Bituminous Materials
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Was test performed on residue from distillation or evaporation?
|
NA
|
|
Soluble, percent
|
99.6 %
|
|
Insoluble, percent
|
0.4 %
|
DIME Test ID: 2022-06-21-47-7
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
Data has not been verified.