| Unit system used? | US Units |
| Number of specimens | 6 |
| Test performed | With no density determined |
| Cross sectional area of cylinder 1 | 28.37 in^2 |
| Cross sectional area of cylinder 2 | 28.27 in^2 |
| Cross sectional area of cylinder 3 | 28.37 in^2 |
| Capped in accordance with? | ASTM C617 - Sulfur Mortar Cap |
| Cross sectional area of cylinder 4 | 28.09 in^2 |
| Cross sectional area of cylinder 5 | 28.18 in^2 |
| Cross sectional area of cylinder 6 | 28.27 in^2 |
| Average diameter of cylinder 1 | 6.01 in |
| Average diameter of cylinder 2 | 6.00 in |
| Compressive strength of cylinder 1 | 722.9 psi |
| Compressive strength of cylinder 2 | 693.8 psi |
| Average diameter of cylinder 3 | 6.01 in |
| Compressive strength of cylinder 3 | 695.3 psi |
| Compressive strength (to nearest 10 psi) | 700 psi |
| Average diameter of cylinder 4 | 5.98 in |
| Compressive strength of cylinder 4 | 694.4 psi |
| Average diameter of cylinder 5 | 5.99 in |
| Compressive strength of cylinder 5 | 690.4 psi |
| Average diameter of cylinder 6 | 6.00 in |
| Compressive strength of cylinder 6 | 683.1 psi |
| Maximum load on cylinder 1 | 20510 lb |
| Maximum load on cylinder 2 | 19615 lb |
| Maximum load on cylinder 3 | 19725 lb |
| Maximum load on cylinder 4 | 19505 lb |
| Maximum load on cylinder 5 | 19455 lb |
| Maximum load on cylinder 6 | 19310 lb |
| Type of fracture pattern of cylinder 1 | 1 |
| Type of fracture pattern of cylinder 2 | 1 |
| Type of fracture pattern of cylinder 3 | 1 |
| Type of fracture pattern of cylinder 4 | 1 |
| Type of fracture pattern of cylinder 5 | 1 |
| Type of fracture pattern of cylinder 6 | 1 |
| Comment on any defect in either specimen or caps (Max 250 Characters) | no data |
| Correction factor for cylinder 1 | 1 |
| Correction factor for cylinder 2 | 1 |
| Correction factor for cylinder 3 | 1 |
| Correction factor for cylinder 4 | 1 |
| Correction factor for cylinder 5 | 1 |
| Correction factor for cylinder 6 | 1 |
| Age of specimen | 7 days |