Project ID: 215456 DEA: 07293604 EFIS: 0713000238
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-405-14.3/15.8
Work Description: CONSTRUCT AUXILIARY LANE AND WIDEN ON AND OFF RAMPS.
Location Description: LOS ANGELES COUNTY IN TORRANCE BETWEEN WESTERN AVENUE UNDERCROSSING AND WEST 182ND STREET
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: 6 CUSHING SUITE 200, IRVINE CA 92618
Resident Engineer: Samuel Gallardo Structure Rep.: James Holloway
DIME Sample ID: 2022-06-27-21
TL Number from the TL Form: 109312
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 06/27/2022
Date that the sample was received by the laboratory/organization performing the testing: 06/28/2022
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 4X8 PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 22-0167
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex
The concrete mix design number: 1612109
The truck number from where the sample was collected: 2
The batch plant ticket number from where the sample was collected: na
Concrete batch plant: Cemex
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-06-27-21-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/05/2022
Date Tested: 07/04/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.02 in
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.69 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4080 psi
|
|
Maximum load on cylinder 1
|
51094 lb
|
|
Maximum load on cylinder 2
|
52110 lb
|
|
Compressive strength of cylinder 1
|
4045.4 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
4106.4 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|
DIME Test ID: 2022-06-27-21-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/11/2022
Date Tested: 07/11/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
4.04 in
|
|
Average diameter of cylinder 2
|
4.03 in
|
|
Cross sectional area of cylinder 1
|
12.82 in^2
|
|
Cross sectional area of cylinder 2
|
12.76 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4680 psi
|
|
Maximum load on cylinder 1
|
59000 lb
|
|
Maximum load on cylinder 2
|
60805 lb
|
|
Compressive strength of cylinder 1
|
4602.2 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
4765.3 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
14 days
|
|
Age of specimen in hours
|
no data0 hours
|
DIME Test ID: 2022-06-27-21-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/01/2022
Date Tested: 07/25/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
4.03 in
|
|
Average diameter of cylinder 2
|
4.01 in
|
|
Cross sectional area of cylinder 1
|
12.76 in^2
|
|
Cross sectional area of cylinder 2
|
12.63 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4600 psi
|
|
Maximum load on cylinder 1
|
60591 lb
|
|
Maximum load on cylinder 2
|
56286 lb
|
|
Compressive strength of cylinder 1
|
4748.5 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
4456.5 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|