Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 031H8504 Cty SAC Rte 5 PM 160-VAR Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Hani Eissa |
Date Reported: |
07/12/2022 |
|
|
Address: |
TL Number: |
174306 |
||
|
City: |
||||
|
Project Name: INSTALL CONNECTOR RAMP METERS & CCTV. |
||||
|
Prime Contractor: Pacific Excavation |
||||
|
Sample Taken Date: |
06/14/2022 |
Mix Design: |
1615674 |
|
|
Contractor: Unknown |
Location : SACRAMENTO COUNTY IN SACRAMENTO AT ROUTE 5/99 SEPARATION AND AT ROUTE 51/160 SEPARATION |
|||
|
Structure unique identifier: |
||||
|
Structure name: |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.02 | 12.69 | 68226 | 5375.0 | 4 |
| 2 | 4.02 | 12.69 | 71586 | 5640.0 | 4 |
| 3 | 4.02 | 12.69 | 62751 | 4944 | 1 |
DIME Test ID: 2022-06-14-17-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5320
Age of specimen: 28 days
Certified By: Spencer Adams
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing