Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993271 DEA: 11430604 EFIS: 1119000026
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8,805-5.6/17.4
Work Description: INSTALL HIGH FRICTION SURFACE TREATMENT
Location Description: FOR CONSTRUCTION ON STATE HIGHWAY IN SAN DIEGO COUNTY IN SAN DIEGO ON ROUTE 8 AT ROUTE 15/8 SEPARATION AND ON ROUTE 805 AT NORTHBOUND 805 TO EASTBOUND 8 CONNECTOR
Contractor Name: HAZARD CONSTRUCTION COMPANY
Contractor Address: 10529 Vine Street, Lakeside, CA, 92040
Resident Engineer: Genaro Genel-Trujillo Structure Rep.: Unknown
DIME Sample ID: 2022-05-11-47
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/11/2022
Date that the sample was received by the laboratory/organization performing the testing: 05/12/2022
The quantity of what the sample constitutes: 2 bags, 12 boxes
A brief description of the sample: 1/2" RHMA-G
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
DIME Test ID: 2022-05-11-47-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/29/2024
Date Tested: 06/14/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: SPEC 7.5 %
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
no data
|
|
Mass of HMA Sample prior to ignition
|
no data
|
|
Corrected Asphalt Binder Content
|
7.41 %
|
|
Mass Loss
|
no data
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.78 %
|
|
Moisture Content
|
no data
|
|
Temperature Compensation Factor
|
no data
|
|
Test Temperature
|
no data
|
DIME Test ID: 2022-05-11-47-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/29/2024
Date Tested: 06/14/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 5802-PSU
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7361.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1560.8 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8286.3 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.454
|
|
Theoretical maximum density at 25°C (77°F)
|
152.7 lb/ft^3
|
DIME Test ID: 2022-05-11-47-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/29/2024
Date Tested: 06/14/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 5802-PSU
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.298
|
|
Bulk Specific Gravity 2
|
2.284
|
|
Bulk Specific Gravity 3
|
2.274
|
|
Average Bulk Specific Gravity
|
2.285
|
DIME Test ID: 2022-05-11-47-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 08/29/2024
Date Tested: 06/16/2022
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 5802-PSU
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
187 psi
|
|
Average Wet Tensile Strength
|
76 psi
|
|
Tensile Strength Ratio
|
40.6
|