| Unit system used? | US Units |
| Number of specimens | 6 |
| Test performed | With no density determined |
| Cross sectional area of cylinder 1 | 27.99 in^2 |
| Cross sectional area of cylinder 2 | 27.99 in^2 |
| Cross sectional area of cylinder 3 | 27.9 in^2 |
| Capped in accordance with? | ASTM C617 - Sulfur Mortar Cap |
| Cross sectional area of cylinder 4 | 28.09 in^2 |
| Cross sectional area of cylinder 5 | 28.09 in^2 |
| Cross sectional area of cylinder 6 | 28.09 in^2 |
| Average diameter of cylinder 1 | 5.97 in |
| Average diameter of cylinder 2 | 5.97 in |
| Compressive strength of cylinder 1 | 557.3 psi |
| Compressive strength of cylinder 2 | 622.7 psi |
| Average diameter of cylinder 3 | 5.96 in |
| Compressive strength of cylinder 3 | 557 psi |
| Compressive strength (to nearest 10 psi) | 580 psi |
| Average diameter of cylinder 4 | 5.98 in |
| Compressive strength of cylinder 4 | 565 psi |
| Average diameter of cylinder 5 | 5.98 in |
| Compressive strength of cylinder 5 | 585.3 psi |
| Average diameter of cylinder 6 | 5.98 in |
| Compressive strength of cylinder 6 | 570.7 psi |
| Maximum load on cylinder 1 | 15600 lb |
| Maximum load on cylinder 2 | 17430 lb |
| Maximum load on cylinder 3 | 15540 lb |
| Maximum load on cylinder 4 | 15870 lb |
| Maximum load on cylinder 5 | 16440 lb |
| Maximum load on cylinder 6 | 16030 lb |
| Type of fracture pattern of cylinder 1 | 2 |
| Type of fracture pattern of cylinder 2 | 2 |
| Type of fracture pattern of cylinder 3 | 2 |
| Type of fracture pattern of cylinder 4 | 2 |
| Type of fracture pattern of cylinder 5 | 2 |
| Type of fracture pattern of cylinder 6 | 2 |
| Comment on any defect in either specimen or caps (Max 250 Characters) | no data |
| Correction factor for cylinder 1 | 1 |
| Correction factor for cylinder 2 | 1 |
| Correction factor for cylinder 3 | 1 |
| Correction factor for cylinder 4 | 1 |
| Correction factor for cylinder 5 | 1 |
| Correction factor for cylinder 6 | 1 |
| Age of specimen | 7 days |