Sample Record for 2022-01-13-44

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214993 DEA: 051F5004 EFIS: 0514000003 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101,135-70.6/71.2;0.1
Work Description: CONSTRUCT CONCRETE BRIDGE, BRIDGE REMOVAL, COLD PLANE, PLACE HMA.
Location Description: SANTA BARBARA COUNTY AT LOS ALAMOS ON ROUTE 101 FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ROUTE 101/135 SEPARATION AND ON ROUTE 135 AT ROUTE 101/135 SEPARATION
Contractor Name: CAL PORTLAND CONSTRUCTION
Contractor Address: 1625 E Donovan Road, Santa Maria, CA 93454
Resident Engineer: Jason Torres Structure Rep.: Alex Martinez

Sample Information

DIME Sample ID: 2022-01-13-44
TL Number from the TL Form:
Sample Submitted By Organization: Kie-Con, Incorporated - Antioch
Sample Organization Contact: (925) 331-7122
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 01/13/2022
Date that the sample was received by the laboratory/organization performing the testing: 01/13/2022
The quantity of what the sample constitutes: 1
A brief description of the sample: 4x8 cylinders
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KIECON

Material Information

The concrete mix design number: K7010-705 CPO R3
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 113281
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Wilbur bed
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 6

DIME Test ID: 2022-01-13-44-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/20/2022
Date Tested: 01/14/2022
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4 mm
Average diameter of cylinder 2 4 mm
Average diameter of cylinder 3 4 mm
Cross sectional area of cylinder 1 12.57 mm^2
Cross sectional area of cylinder 2 12.57 mm^2
Cross sectional area of cylinder 3 12.57 mm^2
Compressive strength (to nearest 0.1MPa) 11779.9 MPa
Maximum load on cylinder 1 149670 N
Maximum load on cylinder 2 144550 N
Maximum load on cylinder 3 150180 N
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 1 days
Age of specimen in hours no data0 hours

Test 2 of 6

DIME Test ID: 2022-01-13-44-2
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/20/2022
Date Tested: 01/20/2022
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4 mm
Average diameter of cylinder 2 4 mm
Average diameter of cylinder 3 4 mm
Cross sectional area of cylinder 1 12.57 mm^2
Cross sectional area of cylinder 2 12.57 mm^2
Cross sectional area of cylinder 3 12.57 mm^2
Compressive strength (to nearest 0.1MPa) 11000.1 MPa
Maximum load on cylinder 1 134390 N
Maximum load on cylinder 2 140080 N
Maximum load on cylinder 3 140470 N
Type of fracture pattern of cylinder 1 4
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 6 days
Age of specimen in hours no data0 hours

Test 3 of 6

DIME Test ID: 2022-01-13-44-3
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/20/2022
Date Tested: 01/27/2022
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4 mm
Average diameter of cylinder 2 4 mm
Average diameter of cylinder 3 4 mm
Cross sectional area of cylinder 1 12.57 mm^2
Cross sectional area of cylinder 2 12.57 mm^2
Cross sectional area of cylinder 3 12.57 mm^2
Compressive strength (to nearest 0.1MPa) 11180.1 MPa
Maximum load on cylinder 1 149110 N
Maximum load on cylinder 2 134690 N
Maximum load on cylinder 3 137960 N
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours

Test 4 of 6

DIME Test ID: 2022-01-13-44-4
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/20/2022
Date Tested: 03/03/2022
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4 mm
Average diameter of cylinder 2 4 mm
Average diameter of cylinder 3 4 mm
Cross sectional area of cylinder 1 12.57 mm^2
Cross sectional area of cylinder 2 12.57 mm^2
Cross sectional area of cylinder 3 12.57 mm^2
Compressive strength (to nearest 0.1MPa) 11770.1 MPa
Maximum load on cylinder 1 144040 N
Maximum load on cylinder 2 152920 N
Maximum load on cylinder 3 147020 N
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours

Test 5 of 6

DIME Test ID: 2022-01-13-44-5
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/20/2022
Date Tested: 03/17/2022
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4 mm
Average diameter of cylinder 2 4 mm
Average diameter of cylinder 3 4 mm
Cross sectional area of cylinder 1 12.57 mm^2
Cross sectional area of cylinder 2 12.57 mm^2
Cross sectional area of cylinder 3 12.57 mm^2
Compressive strength (to nearest 0.1MPa) 11420.1 MPa
Maximum load on cylinder 1 139280 N
Maximum load on cylinder 2 146420 N
Maximum load on cylinder 3 144770 N
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours

Test 6 of 6

DIME Test ID: 2022-01-13-44-6
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/20/2022
Date Tested: 05/19/2022
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4 mm
Average diameter of cylinder 2 4 mm
Average diameter of cylinder 3 4 mm
Cross sectional area of cylinder 1 12.57 mm^2
Cross sectional area of cylinder 2 12.57 mm^2
Cross sectional area of cylinder 3 12.57 mm^2
Compressive strength (to nearest 0.1MPa) 11640.1 MPa
Maximum load on cylinder 1 151950 N
Maximum load on cylinder 2 139830 N
Maximum load on cylinder 3 147040 N
Type of fracture pattern of cylinder 1 4
Type of fracture pattern of cylinder 2 4
Type of fracture pattern of cylinder 3 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours