Print Report | Back to Sample Detail

Sample Record for 2022-05-19-22

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993234 DEA: 051H0004 EFIS: 0516000011 QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-68-1.1/L4.3
Work Description: PLACE HMA AND MODIFY SIGNAL AND LIGHTING SYSTEMS.
Location Description: MONTEREY COUNTY IN AND NEAR PACIFIC GROVE AND MONTEREY FROM FOREST AVENUE TO ROUTE 68/1 SEPARATION
Contractor Name: Graniterock Company
Contractor Address: 350 Technology Drive, Watsonville, CA 95076
Resident Engineer: Tyler Lavering Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-05-19-22
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Sample Organization Contact: 831-818-0254
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/19/2022
Date that the sample was received by the laboratory/organization performing the testing: 05/19/2022
The quantity of what the sample constitutes: 4 Box's HMA-A
A brief description of the sample: 3/4" HMA Type A
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Graniterock Aromas Drum Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 1
Sublot number: 16
HMA Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2022-05-19-22-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/20/2022
Date Tested: 05/19/2022
Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Organization Address: 1529 Salinas Highway,
Organization City: Monterey
Organization State: CA
Organization Zipcode: 93940
Organization Email: wesley.rider@dot.ca.gov
Organization Phone: (831) 818-0254
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 4.79 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) 0.97 %
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data