Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 043A9214 Cty ALA Rte 880 PM 22.6/24.0 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Bahadur Singh |
Date Reported: |
03/05/2015 |
|
Address: |
TL Number: |
1512876C |
||
City: |
||||
Project Name: WIDEN FREEWAY, REPLACE OVERCROSSINGS, AND RECONSTRUCT RAMPS/ROADS. |
||||
Prime Contractor: RGW CONSTRUCTION |
||||
Sample Taken Date: |
01/22/2015 |
Mix Design: |
1512876 |
|
Contractor: Unknown |
Location : ALAMEDA COUNTY IN SAN LEANDRO FROM 0.4 MILE SOUTH OF MARINA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF ROUTE 112/880 SEPARATION |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.46 | 6.02 | 6789.9 | 193240 | 1 |
2 | 28.27 | 6.00 | 6321.2 | 178701 | 1 |
DIME Test ID: 2015-01-22-3-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6560
Age of specimen: 42 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing