Print Report | Back to Sample Detail

Sample Record for 2022-04-28-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214524 DEA: 07304504 EFIS: 0714000067 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-57-R0.0/R4.5
Work Description: CONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK.
Location Description: LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION
Contractor Name: Griffith Company
Contractor Address: 3050 E. Birch Street, Brea, CA 92821
Resident Engineer: Martin Sandoval Structure Rep.: Avtar Bains

Sample Information

DIME Sample ID: 2022-04-28-15
TL Number from the TL Form:
Sample Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Sample Organization Contact: (909) 833-5780
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/28/2022
Date that the sample was received by the laboratory/organization performing the testing: 04/29/2022
The quantity of what the sample constitutes: 370 CY.
A brief description of the sample: A set of 3 JPCP RSC beams
From where was the sample collected: Job Site
Laboratory sample identification: 22-0948
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard at the 57 Freeway

Material Information

The concrete mix design number: HE4X4B
The truck number from where the sample was collected: Load 3
The batch plant ticket number from where the sample was collected: 10637
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-04-28-15-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 05/09/2022
Date Tested: 05/08/2022
Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Organization Address: 620 South Magnolia Avenue, Building G,
Organization City: Ontario
Organization State: CA
Organization Zipcode: 91762
Organization Email: mdorsch@kleinfelder.com
Organization Phone: (909) 833-5780
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 3
Does the testing machine measure load or stress on the beam specimen? Load
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section No
Is a beam dimensional correction factor used? No
Age of specimen 10 days
Modulus of rupture 970 psi
Modulus of rupture 2 940 psi
Modulus of rupture average 955 psi
Modulus of rupture 3 970 psi