Sample Record for 2022-03-07-38
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 22225 DEA: HMA-RSRCH EFIS: HMA-RSRCH
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: In-house research studies for FHWA on Asphalt Mixture Performance Tester (AMPT) and Cracking Tolerance Index of Asphalt Mixtures (IDEAL CT)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2022-03-07-38
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/07/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/07/2022
The quantity of what the sample constitutes: 24 boxes
A brief description of the sample: 1/2" HMA
From where was the sample collected: Supplier
Laboratory sample identification: 022-007
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Pleasanton
Material Information
HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Test Results
Test 1 of 2
DIME Test ID: 2022-03-07-38-1
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
This test has been superseded on 04/15/2022. The corrected test ID is: 2022-03-07-38-2
Reason: retested
Test 2 of 2
DIME Test ID: 2022-03-07-38-2
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Verified Date: 04/15/2022
Date Tested: 04/05/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 172.9 PSI or 1192.2 KPA
Sample #2
The test was superseded from test ID: 2022-03-07-38-1
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
1
|
Test temperature
|
no data
|
Specimen preparation method and aging condition
|
no data
|
Specimen air voids
|
no data
|
Specimen thickness
|
no data
|
Specimen diameter
|
no data
|
Displacement
|
no data
|
Absolute value of the post-peak slope
|
no data
|
Failure energy
|
no data
|
Work of failure
|
no data
|
Cracking tolerance index
|
no data
|
Tests Assigned to this Sample
DIME Test ID | Test Method | Assigned Date | Test Date | Assigned By | Assigned Lab | Test Comments | Assigned To |
2022-03-07-38-3 | ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature | 04/15/2022 | Not scheduled | Juan Gomez | CT HQ - Sacramento Hot Mix Asphalt Laboratory | sample 3, Vulcan Pleasanton | |
2022-03-07-38-4 | ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature | 04/15/2022 | Not scheduled | Juan Gomez | CT HQ - Sacramento Hot Mix Asphalt Laboratory | sample 4, Vulcan Pleasanton | |
2022-03-07-38-5 | ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature | 04/15/2022 | Not scheduled | Juan Gomez | CT HQ - Sacramento Hot Mix Asphalt Laboratory | sample 5, Vulcan Pleasanton | |
2022-03-07-38-6 | ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature | 04/15/2022 | Not scheduled | Juan Gomez | CT HQ - Sacramento Hot Mix Asphalt Laboratory | sample 6, Vulcan Pleasanton | |
2022-03-07-38-7 | ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature | 04/15/2022 | Not scheduled | Juan Gomez | CT HQ - Sacramento Hot Mix Asphalt Laboratory | sample 7, Vulcan Pleasanton | |
2022-03-07-38-8 | ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature | 04/15/2022 | Not scheduled | Juan Gomez | CT HQ - Sacramento Hot Mix Asphalt Laboratory | sample 8, Vulcan Pleasanton | |
2022-03-07-38-9 | ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature | 04/15/2022 | Not scheduled | Juan Gomez | CT HQ - Sacramento Hot Mix Asphalt Laboratory | sample 9, Vulcan Pleasanton | |
2022-03-07-38-10 | ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature | 04/15/2022 | Not scheduled | Juan Gomez | CT HQ - Sacramento Hot Mix Asphalt Laboratory | sample 10, Vulcan Pleasanton | |
2022-03-07-38-11 | ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature | 04/15/2022 | Not scheduled | Juan Gomez | CT HQ - Sacramento Hot Mix Asphalt Laboratory | sample 11, Vulcan Pleasanton | |
2022-03-07-38-12 | ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature | 04/15/2022 | Not scheduled | Juan Gomez | CT HQ - Sacramento Hot Mix Asphalt Laboratory | sample 12, Vulcan Pleasanton | |
55976559775597855979559805598155982559835598455985