Print Report | Back to Sample Detail

Sample Record for 2022-03-07-38

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 22225 DEA: HMA-RSRCH EFIS: HMA-RSRCH QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: In-house research studies for FHWA on Asphalt Mixture Performance Tester (AMPT) and Cracking Tolerance Index of Asphalt Mixtures (IDEAL CT)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-03-07-38
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/07/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/07/2022
The quantity of what the sample constitutes: 24 boxes
A brief description of the sample: 1/2" HMA
From where was the sample collected: Supplier
Laboratory sample identification: 022-007
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Pleasanton

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2022-03-07-38-1
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
This test has been superseded on 04/15/2022. The corrected test ID is: 2022-03-07-38-2
Reason: retested

Test 2 of 2

DIME Test ID: 2022-03-07-38-2
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Verified Date: 04/15/2022
Date Tested: 04/05/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 172.9 PSI or 1192.2 KPA Sample #2
The test was superseded from test ID: 2022-03-07-38-1
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 1
Test temperature no data
Specimen preparation method and aging condition no data
Specimen air voids no data
Specimen thickness no data
Specimen diameter no data
Displacement no data
Absolute value of the post-peak slope no data
Failure energy no data
Work of failure no data
Cracking tolerance index no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2022-03-07-38-3ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature04/15/2022Not scheduledJuan GomezCT HQ - Sacramento Hot Mix Asphalt Laboratorysample 3, Vulcan Pleasanton
2022-03-07-38-4ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature04/15/2022Not scheduledJuan GomezCT HQ - Sacramento Hot Mix Asphalt Laboratorysample 4, Vulcan Pleasanton
2022-03-07-38-5ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature04/15/2022Not scheduledJuan GomezCT HQ - Sacramento Hot Mix Asphalt Laboratorysample 5, Vulcan Pleasanton
2022-03-07-38-6ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature04/15/2022Not scheduledJuan GomezCT HQ - Sacramento Hot Mix Asphalt Laboratorysample 6, Vulcan Pleasanton
2022-03-07-38-7ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature04/15/2022Not scheduledJuan GomezCT HQ - Sacramento Hot Mix Asphalt Laboratorysample 7, Vulcan Pleasanton
2022-03-07-38-8ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature04/15/2022Not scheduledJuan GomezCT HQ - Sacramento Hot Mix Asphalt Laboratorysample 8, Vulcan Pleasanton
2022-03-07-38-9ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature04/15/2022Not scheduledJuan GomezCT HQ - Sacramento Hot Mix Asphalt Laboratorysample 9, Vulcan Pleasanton
2022-03-07-38-10ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature04/15/2022Not scheduledJuan GomezCT HQ - Sacramento Hot Mix Asphalt Laboratorysample 10, Vulcan Pleasanton
2022-03-07-38-11ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature04/15/2022Not scheduledJuan GomezCT HQ - Sacramento Hot Mix Asphalt Laboratorysample 11, Vulcan Pleasanton
2022-03-07-38-12ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature04/15/2022Not scheduledJuan GomezCT HQ - Sacramento Hot Mix Asphalt Laboratorysample 12, Vulcan Pleasanton