Print Report | Back to Sample Detail

Sample Record for 2022-03-22-14

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215456 DEA: 07293604 EFIS: 0713000238 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-405-14.3/15.8
Work Description: CONSTRUCT AUXILIARY LANE AND WIDEN ON AND OFF RAMPS.
Location Description: LOS ANGELES COUNTY IN TORRANCE BETWEEN WESTERN AVENUE UNDERCROSSING AND WEST 182ND STREET
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: 6 CUSHING SUITE 200, IRVINE CA 92618
Resident Engineer: Samuel Gallardo Structure Rep.: James Holloway

Sample Information

DIME Sample ID: 2022-03-22-14
TL Number from the TL Form: 109307
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 03/22/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/24/2022
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 22-0081
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: NA
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 3

DIME Test ID: 2022-03-22-14-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/29/2022
Date Tested: 03/29/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 3620 psi
Maximum load on cylinder 1 106058 lb
Maximum load on cylinder 2 98334 lb
Compressive strength of cylinder 1 3751.6 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3478.4 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 2 of 3

DIME Test ID: 2022-03-22-14-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/05/2022
Date Tested: 04/05/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.01 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.37 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 4110 psi
Maximum load on cylinder 1 116531 lb
Maximum load on cylinder 2 115727 lb
Compressive strength of cylinder 1 4107.5 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4106.7 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 14 days
Age of specimen in hours no data0 hours

Test 3 of 3

DIME Test ID: 2022-03-22-14-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/19/2022
Date Tested: 04/19/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 4400 psi
Maximum load on cylinder 1 122189 lb
Maximum load on cylinder 2 125420 lb
Compressive strength of cylinder 1 4349.9 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4450.7 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours no data0 hours