Print Report | Back to Sample Detail

Sample Record for 2022-03-14-24

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214524 DEA: 07304504 EFIS: 0714000067 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-57-R0.0/R4.5
Work Description: CONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK.
Location Description: LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION
Contractor Name: Griffith Company
Contractor Address: 3050 E. Birch Street, Brea, CA 92821
Resident Engineer: Martin Sandoval Structure Rep.: Avtar Bains

Sample Information

DIME Sample ID: 2022-03-14-24
TL Number from the TL Form:
Sample Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Sample Organization Contact: (909) 833-5780
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 03/14/2022
Date that the sample was received by the laboratory/organization performing the testing: 03/15/2022
The quantity of what the sample constitutes: 204 CY
A brief description of the sample: A set of 2 LCB cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 22-0483
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard at the 57 Freeway

Material Information

The concrete mix design number: 57030SL
The truck number from where the sample was collected: Load 4
The batch plant ticket number from where the sample was collected: NOT PROVIDED
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-03-14-24-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/21/2022
Date Tested: 03/21/2022
Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Organization Address: 620 South Magnolia Avenue, Building G,
Organization City: Ontario
Organization State: CA
Organization Zipcode: 91762
Organization Email: mdorsch@kleinfelder.com
Organization Phone: (909) 833-5780
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? no data
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.98 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.09 in^2
Compressive strength (to nearest 10 psi) 4670 psi
Maximum load on cylinder 1 130140 lb
Maximum load on cylinder 2 132180 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data