DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # Cty Rte PM Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Unknown |
Date Reported: |
11/26/2014 |
|
|
Address: |
TL Number: |
87427 |
||
|
City: |
||||
|
Project Name: Crush test |
||||
|
Prime Contractor: Not set |
||||
|
Sample Taken Date: |
11/19/2014 |
Mix Design: |
xxxxxxxxxxxxxxxxxxx |
|
|
Contractor: Unknown |
Location : |
|||
|
Structure unique identifier: Unknown |
||||
|
Structure name: CHP Academy |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 28.27 | 6.00 | 3762.9 | 106377 | 2 |
| 2 | 28.37 | 6.01 | 3864.1 | 109625 | 1 |
DIME Test ID: 2014-11-19-1-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3810
Comment on any defect in either specimen or caps (Max 250 Characters): Cylinder #1 diameters are not in compliance. w/ ASTM C39 section 6.1. Diameters measured differ more than 2%.
Age of specimen: 7 days
Certified By: She Vang
Test ID: 2014-11-19-1-1: Cylinder #1 average diameters are not within 2% requirement Please check cylinder molds.
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing